Search
×
FR

Placeholder headline

This is just a placeholder headline

API STD 521: Guide for Pressure-relieving and Depressuring Systems – Edition 6

$

682

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 653: Tank Inspection, Repair, Alteration, and Reconstruction – Edition 4

$

507

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:19 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series-18: Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z246.2-14 – Emergency preparedness and response for petroleum and natural gas industry systems

$

596

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:22 – Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z731-09 (R2014) – Emergency Preparedness and Response

$

177

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:23 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:26 – Storage of Hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA B51:24 Boiler, Pressure Vessel, and Pressure Piping Code

$

389

BUY NOW

ISO 5725:2023

ISO 5725:2023 Accuracy (trueness and precision) of measurement methods and results – Part 3: Intermediate precision and alternative designs for collaborative studies

CDN $379.00

SKU: 11e28ffc24aa Categories: ,

Description

This document provides

a)    a discussion of alternative experimental designs for the determination of trueness and precision measures including reproducibility, repeatability and selected measures of intermediate precision of a standard measurement method, including a review of the circumstances in which their use is necessary or beneficial, and guidance as to the interpretation and application of the resulting estimates, and

b)    worked examples including specific designs and computations.

Each of the alternative designs discussed in this document is intended to address one (or several) of the following issues:

a)    a discussion of the implications of the definitions of intermediate precision measures;

b)    a guidance on the interpretation and application of the estimates of intermediate precision measures in practical situations;

c)    determining reproducibility, repeatability and selected measures of intermediate precision;

d)    improved determination of reproducibility and other measures of precision;

e)    improving the estimate of the sample mean;

f)     determining the range of in-house repeatability standard deviations;

g)    determining other precision components such as operator variability;

h)    determining the level of reliability of precision estimates;

i)     reducing the minimum number of participating laboratories by optimizing the reliability of precision estimates;

j)     avoiding distorted estimations of repeatability (split-level designs);

k)    avoiding distorted estimations of reproducibility (taking the heterogeneity of the material into consideration).

Often, the performance of the method whose precision is being evaluated in a collaborative study will have previously been assessed in a single-laboratory validation study conducted by the laboratory which developed it. Relevant factors for the determination of intermediary precision will have been identified in this prior single-laboratory study.

Edition

2

Published Date

2023-06-28

Status

PUBLISHED

Pages

57

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document provides

a)    a discussion of alternative experimental designs for the determination of trueness and precision measures including reproducibility, repeatability and selected measures of intermediate precision of a standard measurement method, including a review of the circumstances in which their use is necessary or beneficial, and guidance as to the interpretation and application of the resulting estimates, and

b)    worked examples including specific designs and computations.

Each of the alternative designs discussed in this document is intended to address one (or several) of the following issues:

a)    a discussion of the implications of the definitions of intermediate precision measures;

b)    a guidance on the interpretation and application of the estimates of intermediate precision measures in practical situations;

c)    determining reproducibility, repeatability and selected measures of intermediate precision;

d)    improved determination of reproducibility and other measures of precision;

e)    improving the estimate of the sample mean;

f)     determining the range of in-house repeatability standard deviations;

g)    determining other precision components such as operator variability;

h)    determining the level of reliability of precision estimates;

i)     reducing the minimum number of participating laboratories by optimizing the reliability of precision estimates;

j)     avoiding distorted estimations of repeatability (split-level designs);

k)    avoiding distorted estimations of reproducibility (taking the heterogeneity of the material into consideration).

Often, the performance of the method whose precision is being evaluated in a collaborative study will have previously been assessed in a single-laboratory validation study conducted by the laboratory which developed it. Relevant factors for the determination of intermediary precision will have been identified in this prior single-laboratory study.

Previous Editions

Can’t find what you are looking for?

Please contact us at: