ISO 13693:2015
ISO 13693:2015 Irrigation equipment – Safety devices for chemigation – Part 2: Chemigation valve assemblies from DN 75 (3″) to DN 350 (14″)
CDN $115.00
Description
ISO 13693-2:2015 specifies the construction and performance requirement and test methods for metal-bodied chemigation valves with water at temperatures not exceeding 50 °C, which might contain fertilizers and chemicals of the types and concentration used in agriculture.
The valve is designed to prohibit backflow caused by either back pressure or back siphonage. It is not designed for use in potable water systems. It is not to be confused with other forms of backflow prevention devices including pressure vacuum breakers, double check valves, reduced pressure zone valves, or goose neck loops. ISO 13693-2:2015 specifies the minimum design, construction, and performance testing requirements for the chemigation valve assembly. The assembly consists of the following components: ? a valve body into which a spring-loaded check valve is mounted with a resilient disk cover on the sealing surface; a combination air release/vacuum relief valve located upstream of the check valve; a low pressure drain valve located upstream of the check valve; an inspection port located so as to permit visual and manual inspection of the valve working components.
Edition
1
Published Date
2015-02-11
Status
PUBLISHED
Pages
8
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
ISO 13693-2:2015 specifies the construction and performance requirement and test methods for metal-bodied chemigation valves with water at temperatures not exceeding 50 °C, which might contain fertilizers and chemicals of the types and concentration used in agriculture.
The valve is designed to prohibit backflow caused by either back pressure or back siphonage. It is not designed for use in potable water systems. It is not to be confused with other forms of backflow prevention devices including pressure vacuum breakers, double check valves, reduced pressure zone valves, or goose neck loops. ISO 13693-2:2015 specifies the minimum design, construction, and performance testing requirements for the chemigation valve assembly. The assembly consists of the following components: ? a valve body into which a spring-loaded check valve is mounted with a resilient disk cover on the sealing surface; a combination air release/vacuum relief valve located upstream of the check valve; a low pressure drain valve located upstream of the check valve; an inspection port located so as to permit visual and manual inspection of the valve working components.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 21276:2018 Clean cookstoves and clean cooking solutions – Vocabulary
CDN $76.00 Add to cart -

ISO 41011:2024 Facility management – Vocabulary
CDN $233.00 Add to cart -

ISO 6165:2022 Earth-moving machinery – Basic types – Identification and vocabulary
CDN $76.00 Add to cart -

ISO 1956:1982 Fruits and vegetables – Morphological and structural terminology
CDN $233.00 Add to cart