ISO 19880:2020
ISO 19880:2020 Gaseous hydrogen – Fuelling stations – Part 1: General requirements
CDN $422.00
Description
This document defines the minimum design, installation, commissioning, operation, inspection and maintenance requirements, for the safety, and, where appropriate, for the performance of public and non-public fuelling stations that dispense gaseous hydrogen to light duty road vehicles (e.g. fuel cell electric vehicles).
This document is not applicable to the dispensing of cryogenic hydrogen, or hydrogen to metal hydride applications.
Since this document is intended to provide minimum requirements for fuelling stations, manufacturers can take additional safety precautions as determined by a risk management methodology to address potential safety risks of specific designs and applications.
While this document is targeted for the fuelling of light duty hydrogen road vehicles, requirements and guidance for fuelling medium and heavy duty road vehicles (e.g. buses, trucks) are also covered.
Many of the generic requirements within this document are applicable to fuelling stations for other hydrogen applications, including but not limited to the following:
– fuelling stations for motorcycles, fork-lift trucks, trams, trains, fluvial and marine applications;
– fuelling stations with indoor dispensing;
– residential applications to fuel land vehicles;
– mobile fuelling stations; and
– non-public demonstration fuelling stations.
However, further specific requirements that can be necessary for the safe operation of such fuelling stations are not addressed in this document.
This document provides requirements for and guidance on the following elements of a fuelling station (see Figure 1 and Figure 2):
– hydrogen production/delivery system:
- – delivery of hydrogen by pipeline, trucked in gaseous and/or liquid hydrogen, or metal hydride storage trailers;
- – on-site hydrogen generators using water electrolysis process or hydrogen generators using fuel processing technologies;
- – liquid hydrogen storage;
- – hydrogen purification systems, as applicable;
– compression:
- – gaseous hydrogen compression;
- – pumps and vaporizers;
– gaseous hydrogen buffer storage;
– pre-cooling device;
– gaseous hydrogen dispensing systems.
Edition
1
Published Date
2020-03-04
Status
PUBLISHED
Pages
173
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
This document defines the minimum design, installation, commissioning, operation, inspection and maintenance requirements, for the safety, and, where appropriate, for the performance of public and non-public fuelling stations that dispense gaseous hydrogen to light duty road vehicles (e.g. fuel cell electric vehicles).
This document is not applicable to the dispensing of cryogenic hydrogen, or hydrogen to metal hydride applications.
Since this document is intended to provide minimum requirements for fuelling stations, manufacturers can take additional safety precautions as determined by a risk management methodology to address potential safety risks of specific designs and applications.
While this document is targeted for the fuelling of light duty hydrogen road vehicles, requirements and guidance for fuelling medium and heavy duty road vehicles (e.g. buses, trucks) are also covered.
Many of the generic requirements within this document are applicable to fuelling stations for other hydrogen applications, including but not limited to the following:
- fuelling stations for motorcycles, fork-lift trucks, trams, trains, fluvial and marine applications;
- fuelling stations with indoor dispensing;
- residential applications to fuel land vehicles;
- mobile fuelling stations; and
- non-public demonstration fuelling stations.
However, further specific requirements that can be necessary for the safe operation of such fuelling stations are not addressed in this document.
This document provides requirements for and guidance on the following elements of a fuelling station (see Figure 1 and Figure 2):
- hydrogen production/delivery system:
- - delivery of hydrogen by pipeline, trucked in gaseous and/or liquid hydrogen, or metal hydride storage trailers;
- - on-site hydrogen generators using water electrolysis process or hydrogen generators using fuel processing technologies;
- - liquid hydrogen storage;
- - hydrogen purification systems, as applicable;
- compression:
- - gaseous hydrogen compression;
- - pumps and vaporizers;
- gaseous hydrogen buffer storage;
- pre-cooling device;
- gaseous hydrogen dispensing systems.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 2382:2015 Information technology – Vocabulary
CDN $0.00 Add to cart -

ISO 5053:2019 Industrial trucks – Vocabulary – Part 2: Fork arms and attachments
CDN $379.00 Add to cart -

ISO 80004:2020 Nanotechnologies – Vocabulary – Part 3: Carbon nano-objects
CDN $82.00 Add to cart -

ISO 612:1978 Road vehicles – Dimensions of motor vehicles and towed vehicles – Terms and definitions
CDN $186.00 Add to cart