ISO 21726:2019
ISO 21726:2019 Biological evaluation of medical devices – Application of the threshold of toxicological concern (TTC) for assessing biocompatibility of medical device constituents
CDN $115.00
Description
This document describes the basis for, selection of, and general applicability of a threshold of toxicological concern (TTC) value for a constituent present in/on a medical device or released from a medical device. The TTC values in this document can be used for:
– comparing to a maximum concentration of an identified or unidentified constituent in an extract (see ISO 10993-18);
– supporting toxicological equivalence;
– comparing to a maximum exposure dose estimate of an identified constituent (see ISO 10993-17).
NOTE Constituent is defined in 3.1.
ISO 10993-18 specifies how to convert TTC (µg/d) into a concentration (µg/ml).
TTC is not applicable to constituents with adequate toxicity data for deriving a tolerable intake (TI) value (see ISO 10993-17).
The TTC values established in this document are protective for carcinogens, systemic toxicants, and reproductive toxicants (see Clause 5). This document does not include TTC values for other biological endpoints assessed as part of the biological evaluation of a medical device, per ISO 10993-1, for example:
– cytotoxicity;
– irritation;
– sensitization;
– hemocompatibility;
– material mediated pyrogenicity;
– local effects that occur in tissues at the site of contact between a medical device and the body (e.g. the observations from implantation studies).
The TTC values in this document do not apply to potential exposure via gas pathways of medical devices. For application of TTC for constituents present/released from these devices, see the ISO 18562 series.
The TTC values presented in this document are not applicable for the safety assessment of cohort of concern (see 5.3).
Edition
1
Published Date
2019-02-01
Status
PUBLISHED
Pages
7
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
This document describes the basis for, selection of, and general applicability of a threshold of toxicological concern (TTC) value for a constituent present in/on a medical device or released from a medical device. The TTC values in this document can be used for:
- comparing to a maximum concentration of an identified or unidentified constituent in an extract (see ISO 10993-18);
- supporting toxicological equivalence;
- comparing to a maximum exposure dose estimate of an identified constituent (see ISO 10993-17).
NOTE Constituent is defined in 3.1.
ISO 10993-18 specifies how to convert TTC (µg/d) into a concentration (µg/ml).
TTC is not applicable to constituents with adequate toxicity data for deriving a tolerable intake (TI) value (see ISO 10993-17).
The TTC values established in this document are protective for carcinogens, systemic toxicants, and reproductive toxicants (see Clause 5). This document does not include TTC values for other biological endpoints assessed as part of the biological evaluation of a medical device, per ISO 10993-1, for example:
- cytotoxicity;
- irritation;
- sensitization;
- hemocompatibility;
- material mediated pyrogenicity;
- local effects that occur in tissues at the site of contact between a medical device and the body (e.g. the observations from implantation studies).
The TTC values in this document do not apply to potential exposure via gas pathways of medical devices. For application of TTC for constituents present/released from these devices, see the ISO 18562 series.
The TTC values presented in this document are not applicable for the safety assessment of cohort of concern (see 5.3).
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 16782:2016 Clinical laboratory testing – Criteria for acceptable lots of dehydrated Mueller-Hinton agar and broth for antimicrobial susceptibility testing
CDN $233.00 Add to cart -

ISO 10993:2018 Biological evaluation of medical devices – Part 1: Evaluation and testing within a risk management process
CDN $360.00 Add to cart -

ISO 10993:2025 Biological evaluation of medical devices – Part 4: Selection of tests for interactions with blood – Amendment 1
CDN $32.00 Add to cart -

ISO 10993:2022 Biological evaluation of medical devices – Part 2: Animal welfare requirements
CDN $173.00 Add to cart