REGISTER

FR
Search
×
FR

Placeholder headline

This is just a placeholder headline

API TR 2583 : Measurement of Produced Water for Custody Transfer

$

174

BUY NOW

Placeholder headline

This is just a placeholder headline

API TR 2581: Wet Gas Sampling

$

189

BUY NOW

Placeholder headline

This is just a placeholder headline

API TR 2581 Wet Gas Sampling : Errata 1

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

API 510: Pressure Vessel Inspection Code: In-service Inspection, Rating, Repair, and Alteration

$

481

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 6AV1: Validation of Safety and Shutdown Valves for Sandy Service : Edition 4

$

208

BUY NOW

Placeholder headline

This is just a placeholder headline

API 510: Errata 2

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 16B Coiled Tubing, Snubbing and Wireline Well Intervention Equipment

$

189

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 5CT: Casing and Tubing w/ Addendum 1

$

518

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 5CT: Casing and Tubing Addendum 1

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 1161: Hazardous Liquid Pipeline Operator Qualification (OQ) : Edition 6

$

301

BUY NOW

ISO 18250:2018

ISO 18250:2018 Medical devices – Connectors for reservoir delivery systems for healthcare applications – Part 7: Connectors for intravascular infusion

CDN $273.00

SKU: 83dfac09c1e5 Category:

Description

This document specifies the interface dimensions and requirements for the design and functional performance of connectors intended to be used to connect intravascular infusion sets to intravascular infusion reservoirs.

This document does not specify the dimensions and requirements for the medical devices or accessories that use these connectors. Such requirements are given in particular international standards for specific medical devices or accessories.

EXAMPLES Medical devices which may use intravascular reservoir connectors are the following:

– Administration ports on IV fluid reservoirs and the mating spikes of IV administration/intravascular infusion sets/lines, e.g., IV bags/containers and the spike inlet ends of IV sets;

– Devices intended to be connected in series between the administration port of IV fluid reservoirs and the mating spikes of IV administration/giving lines;

– Syringes and syringe IV sets utilizing Luer connectors.

The following connectors are excluded from the scope of this document:

– Stoppers for bottles as specified in ISO 8536-2;

– Compounding/admixture ports on IV reservoirs and intended mating devices.

EXAMPLES Rubber stoppers used for injection into the reservoir and the mating pharmacy admixture devices (syringes, needles, reconstitution devices, and other ancillary equipment used to access the compounding or admixture ports).

– The fill ports of non-powered (i.e. elastomeric) pumps.

NOTE 1 Details of alternative spikes that are in common use are located in Annex G for informational purposes.

NOTE 2 Manufacturers are encouraged to incorporate the connectors specified in this document into intravascular infusion medical devices or accessories, even if not currently required by the particular medical device standards. It is expected that when the particular medical device standards are revised, requirements for reservoir connectors, as specified in ISO 18250, will be included.

Edition

1

Published Date

2018-12-17

Status

PUBLISHED

Pages

34

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies the interface dimensions and requirements for the design and functional performance of connectors intended to be used to connect intravascular infusion sets to intravascular infusion reservoirs.

This document does not specify the dimensions and requirements for the medical devices or accessories that use these connectors. Such requirements are given in particular international standards for specific medical devices or accessories.

EXAMPLES Medical devices which may use intravascular reservoir connectors are the following:

- Administration ports on IV fluid reservoirs and the mating spikes of IV administration/intravascular infusion sets/lines, e.g., IV bags/containers and the spike inlet ends of IV sets;

- Devices intended to be connected in series between the administration port of IV fluid reservoirs and the mating spikes of IV administration/giving lines;

- Syringes and syringe IV sets utilizing Luer connectors.

The following connectors are excluded from the scope of this document:

- Stoppers for bottles as specified in ISO 8536-2;

- Compounding/admixture ports on IV reservoirs and intended mating devices.

EXAMPLES Rubber stoppers used for injection into the reservoir and the mating pharmacy admixture devices (syringes, needles, reconstitution devices, and other ancillary equipment used to access the compounding or admixture ports).

- The fill ports of non-powered (i.e. elastomeric) pumps.

NOTE 1 Details of alternative spikes that are in common use are located in Annex G for informational purposes.

NOTE 2 Manufacturers are encouraged to incorporate the connectors specified in this document into intravascular infusion medical devices or accessories, even if not currently required by the particular medical device standards. It is expected that when the particular medical device standards are revised, requirements for reservoir connectors, as specified in ISO 18250, will be included.

Previous Editions

Can’t find what you are looking for?

Please contact us at: