Search
×
FR

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-6 Chapter 6 – Density

$

204

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 560: Fired Heaters for General Refinery Services

$

721

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 64: Diverter Equipment Systems

$

324

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 17.10.1: Refrigerated Light Hydrocarbon Fluids – Measurement of Cargoes on Board LNG Carries

$

417

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-1: Testing Water-based Drilling Fluids

$

418

BUY NOW

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-12 Chapter 12 – Thermal Conductivity

$

214

BUY NOW

Placeholder headline

This is just a placeholder headline

API 16FI Frac Iron Guidelines and Requirements

$

129

BUY NOW

ISO 9170:2017

ISO 9170:2017 Terminal units for medical gas pipeline systems – Part 1: Terminal units for use with compressed medical gases and vacuum

CDN $233.00

SKU: 7121ce01f7e6 Categories: ,

Description

ISO 9170-1:2017 is intended especially to ensure the gas-specific assembly, mechanical resistance, flow, leakage and pressure drop of terminal units and to prevent their interchange between different gases and services and applies to terminal units:

a) intended for use in medical gas pipeline systems in accordance with ISO 7396‚Äë1;

b) used as pressure outlets on pressure regulators in accordance with ISO 10524‚Äë1;

c) used as pressure outlets on pressure regulators integrated with cylinder valves (VIPR) in accordance with ISO 10524‚Äë3.

ISO 9170-1:2017 applies to terminal units for use with the following gases for administration to patients or for medical uses (A):

– oxygen (A);

– nitrous oxide (A);

– medical air (A);

– carbon dioxide (A);

– oxygen/nitrous oxide mixture (A);

– helium/oxygen mixtures (A);

– oxygen 93 (A);

– gases and gas mixtures classified as medical device (A);

– gases delivered to medical devices or intended for medical purposes (A);

– gases and gas mixtures for medicinal use not specified above (A).

ISO 9170-1:2017 applies to terminal units for use with the following gases (B):

– air for driving surgical tools (B);

– nitrogen for driving surgical tools (B).

This document applies to terminal units for use with vacuum systems (C).

NOTE The requirements of this document can be used as guidelines for terminal units for other gases. These other gases will be considered for inclusion in this document when they come into general use.

ISO 9170-1:2017 specifies requirements for terminal units for supply and disposal of nitrogen and air for driving surgical tools.

ISO 9170-1:2017 specifies requirements for probes intended to be connected to the gas-specific connection point.

ISO 9170-1:2017 does not specify the dimensions of probes or of the gas-specific connection points.

NOTE Regional or national standards specifying dimensions of probes and gas-specific connection points are given in the Bibliography.

Other connection systems in national use may be acceptable under this document. Dimensioning for such connections will be specified by their respective national standards.

ISO 9170-1:2017 does not specify the requirements for terminal units for anaesthetic gas scavenging systems (AGSS), which are specified in ISO 9170‚Äë2.

Edition

3

Published Date

2017-07-24

Status

PUBLISHED

Pages

25

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO 9170-1:2017 is intended especially to ensure the gas-specific assembly, mechanical resistance, flow, leakage and pressure drop of terminal units and to prevent their interchange between different gases and services and applies to terminal units:

a) intended for use in medical gas pipeline systems in accordance with ISO 7396‚Äë1;

b) used as pressure outlets on pressure regulators in accordance with ISO 10524‚Äë1;

c) used as pressure outlets on pressure regulators integrated with cylinder valves (VIPR) in accordance with ISO 10524‚Äë3.

ISO 9170-1:2017 applies to terminal units for use with the following gases for administration to patients or for medical uses (A):

- oxygen (A);

- nitrous oxide (A);

- medical air (A);

- carbon dioxide (A);

- oxygen/nitrous oxide mixture (A);

- helium/oxygen mixtures (A);

- oxygen 93 (A);

- gases and gas mixtures classified as medical device (A);

- gases delivered to medical devices or intended for medical purposes (A);

- gases and gas mixtures for medicinal use not specified above (A).

ISO 9170-1:2017 applies to terminal units for use with the following gases (B):

- air for driving surgical tools (B);

- nitrogen for driving surgical tools (B).

This document applies to terminal units for use with vacuum systems (C).

NOTE The requirements of this document can be used as guidelines for terminal units for other gases. These other gases will be considered for inclusion in this document when they come into general use.

ISO 9170-1:2017 specifies requirements for terminal units for supply and disposal of nitrogen and air for driving surgical tools.

ISO 9170-1:2017 specifies requirements for probes intended to be connected to the gas-specific connection point.

ISO 9170-1:2017 does not specify the dimensions of probes or of the gas-specific connection points.

NOTE Regional or national standards specifying dimensions of probes and gas-specific connection points are given in the Bibliography.

Other connection systems in national use may be acceptable under this document. Dimensioning for such connections will be specified by their respective national standards.

ISO 9170-1:2017 does not specify the requirements for terminal units for anaesthetic gas scavenging systems (AGSS), which are specified in ISO 9170‚Äë2.

Previous Editions

Can’t find what you are looking for?

Please contact us at: