Search
×
FR

Placeholder headline

This is just a placeholder headline

API TR 5C3: Calculating Performance Properties of Pipe Used as Casing or Tubing

$

422

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 671: Special Purpose Couplings for Petroleum, Chemical and Gas Industry Services

$

502

BUY NOW

Placeholder headline

This is just a placeholder headline

Technical Report API TBD-10: Chapter 10 Surface and Interfacial Tension

$

176

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 671: Special Purpose Couplings for Petroleum, Chemical and Gas Industry Services: Errata 2

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

MSS SP-44-2026: Steel Pipeline Flanges

$

450

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 576: Inspection of Pressure-relieving Devices

$

460

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 591: Process Valve Qualification Procedure

$

226

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 576: Inspection of Pressure-relieving Devices: Addendum 1

$

0

BUY NOW

ISO 10993:2016

ISO 10993:2016 Biological evaluation of medical devices – Part 6: Tests for local effects after implantation

CDN $273.00

SKU: c1e85e2715bf Categories: ,

Description

ISO 10993-6:2016 specifies test methods for the assessment of the local effects after implantation of biomaterials intended for use in medical devices.

ISO 10993-6:2016 applies to materials that are

– solid and non-absorbable,

– non-solid, such as porous materials, liquids, gels, pastes, and particulates, and

– degradable and/or absorbable, which may be solid or non-solid.

The test sample is implanted into a site and animal species appropriate for the evaluation of the biological safety of the material. These implantation tests are not intended to evaluate or determine the performance of the test sample in terms of mechanical or functional loading. This part of ISO 10993 can also be applied to medical devices that are intended to be used topically in clinical indications where the surface or lining might have been breached, in order to evaluate local tissue responses.

The local effects are evaluated by a comparison of the tissue response caused by a test sample to that caused by control materials used in medical devices whose clinical acceptability and biocompatibility characteristics have been established. The objective of the test methods is to characterize the history and evolution of the tissue response after implantation of a medical device/biomaterial including final integration or absorption/degradation of the material. In particular for degradable/absorbable materials, the degradation characteristics of the material and the resulting tissue response should be determined.

ISO 10993-6:2016 does not deal with systemic toxicity, carcinogenicity, teratogenicity or mutagenicity. However, the long-term implantation studies intended for evaluation of local biological effects might provide insight into some of these properties. Systemic toxicity studies conducted by implantation might satisfy the requirements of this part of ISO 10993. When conducting combined studies for evaluating local effects and systemic effects, the requirements of both standards is to be fulfilled.

Edition

3

Published Date

2016-11-28

Status

PUBLISHED

Pages

29

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO 10993-6:2016 specifies test methods for the assessment of the local effects after implantation of biomaterials intended for use in medical devices.

ISO 10993-6:2016 applies to materials that are

- solid and non-absorbable,

- non-solid, such as porous materials, liquids, gels, pastes, and particulates, and

- degradable and/or absorbable, which may be solid or non-solid.

The test sample is implanted into a site and animal species appropriate for the evaluation of the biological safety of the material. These implantation tests are not intended to evaluate or determine the performance of the test sample in terms of mechanical or functional loading. This part of ISO 10993 can also be applied to medical devices that are intended to be used topically in clinical indications where the surface or lining might have been breached, in order to evaluate local tissue responses.

The local effects are evaluated by a comparison of the tissue response caused by a test sample to that caused by control materials used in medical devices whose clinical acceptability and biocompatibility characteristics have been established. The objective of the test methods is to characterize the history and evolution of the tissue response after implantation of a medical device/biomaterial including final integration or absorption/degradation of the material. In particular for degradable/absorbable materials, the degradation characteristics of the material and the resulting tissue response should be determined.

ISO 10993-6:2016 does not deal with systemic toxicity, carcinogenicity, teratogenicity or mutagenicity. However, the long-term implantation studies intended for evaluation of local biological effects might provide insight into some of these properties. Systemic toxicity studies conducted by implantation might satisfy the requirements of this part of ISO 10993. When conducting combined studies for evaluating local effects and systemic effects, the requirements of both standards is to be fulfilled.