Search
×
FR

Placeholder headline

This is just a placeholder headline

API TR 5C3: Calculating Performance Properties of Pipe Used as Casing or Tubing

$

422

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 671: Special Purpose Couplings for Petroleum, Chemical and Gas Industry Services

$

502

BUY NOW

Placeholder headline

This is just a placeholder headline

Technical Report API TBD-10: Chapter 10 Surface and Interfacial Tension

$

176

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 671: Special Purpose Couplings for Petroleum, Chemical and Gas Industry Services: Errata 2

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

MSS SP-44-2026: Steel Pipeline Flanges

$

450

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 576: Inspection of Pressure-relieving Devices

$

460

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 591: Process Valve Qualification Procedure

$

226

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 576: Inspection of Pressure-relieving Devices: Addendum 1

$

0

BUY NOW

ISO 13022:2012

ISO 13022:2012 Medical products containing viable human cells – Application of risk management and requirements for processing practices

CDN $312.00

SKU: 1475ce396d19 Category:

Description

This International Standard specifies requirements and guidance for processing practices and managing risk

associated with viable cellular components of products regulated as medicinal products, biologics, medical

devices and active implantable medical devices, or combinations thereof. It covers viable human materials of

autologous as well as allogeneic human origin, obtained from living or deceased donors.

For manufacturers of medical products containing viable cells of human origin, this International Standard

specifies procedures to be used in processing and handling, as well as those to be used in identifying the

hazards and hazardous situations associated with such cells, in order to estimate and evaluate the resulting

risks, to control these risks, and to monitor the effectiveness of that control. Furthermore, this International

Standard outlines the decision process for the residual risk acceptability, taking into account the balance of

residual risk and expected medical benefit as compared to available alternatives.

This International Standard provides requirements and guidance on risk management related to the hazards

typical of medical products manufactured utilizing viable human materials, such as:

a) contamination by bacteria, moulds, yeasts or parasites;

b) contamination by viruses;

c) contamination by agents causing Transmissible Spongiform Encephalopathies (TSE);

d) contaminating material responsible for undesired pyrogenic, immunological or toxicological reactions;

e) decomposition of the product and degradation products caused by inadequate handling;

f) hazards related to the tumorigenic potential of the cell types used;

g) complications resulting from unintended physiological and anatomical consequences (this includes

unintended migration of cells, unwanted release of biologically active substances such as hormones and

cytokines, and unintended interactions between cellular and non‚Äëcellular components of the product);

h) failure of traceability;

i) complications resulting from the material eliciting an unintended immunogenic reaction.

For the evaluation of contamination with other unclassified pathogenic entities, similar principles might be applicable.

Hazards related to genetic modification are outside the scope of this International Standard and are

addressed elsewhere.

NOTE 1 A definition of “genetically modified” can be found in ASTM F2312.

NOTE 2 This International Standard does not specify a quality management system for the control of all stages of

production of medical products as described above.

If additional national or regional criteria beyond what is defined in this International Standard exist in the

country where the medical product will be used, they are also applicable.

NOTE 3 Regional requirements can be more stringent than requirements referenced in this International Standard,

especially with regard to donor eligibility criteria.

This International Standard is not applicable to:

– non‚Äëviable materials of human origin;

– viable cells of non‚Äëhuman origin;

– blood and its components used for transfusion, germ cells, organs and bone marrow used for transplantation,

and other tissues that do not meet the definition of “medical product”;

in vitro diagnostic devices.

NOTE 4 For guidance on the application of this International Standard, see Annex A.

Edition

1

Published Date

2012-03-21

Status

PUBLISHED

Pages

48

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This International Standard specifies requirements and guidance for processing practices and managing risk

associated with viable cellular components of products regulated as medicinal products, biologics, medical

devices and active implantable medical devices, or combinations thereof. It covers viable human materials of

autologous as well as allogeneic human origin, obtained from living or deceased donors.

For manufacturers of medical products containing viable cells of human origin, this International Standard

specifies procedures to be used in processing and handling, as well as those to be used in identifying the

hazards and hazardous situations associated with such cells, in order to estimate and evaluate the resulting

risks, to control these risks, and to monitor the effectiveness of that control. Furthermore, this International

Standard outlines the decision process for the residual risk acceptability, taking into account the balance of

residual risk and expected medical benefit as compared to available alternatives.

This International Standard provides requirements and guidance on risk management related to the hazards

typical of medical products manufactured utilizing viable human materials, such as:

a) contamination by bacteria, moulds, yeasts or parasites;

b) contamination by viruses;

c) contamination by agents causing Transmissible Spongiform Encephalopathies (TSE);

d) contaminating material responsible for undesired pyrogenic, immunological or toxicological reactions;

e) decomposition of the product and degradation products caused by inadequate handling;

f) hazards related to the tumorigenic potential of the cell types used;

g) complications resulting from unintended physiological and anatomical consequences (this includes

unintended migration of cells, unwanted release of biologically active substances such as hormones and

cytokines, and unintended interactions between cellular and non‚Äëcellular components of the product);

h) failure of traceability;

i) complications resulting from the material eliciting an unintended immunogenic reaction.

For the evaluation of contamination with other unclassified pathogenic entities, similar principles might be applicable.

Hazards related to genetic modification are outside the scope of this International Standard and are

addressed elsewhere.

NOTE 1 A definition of "genetically modified" can be found in ASTM F2312.

NOTE 2 This International Standard does not specify a quality management system for the control of all stages of

production of medical products as described above.

If additional national or regional criteria beyond what is defined in this International Standard exist in the

country where the medical product will be used, they are also applicable.

NOTE 3 Regional requirements can be more stringent than requirements referenced in this International Standard,

especially with regard to donor eligibility criteria.

This International Standard is not applicable to:

- non‚Äëviable materials of human origin;

- viable cells of non‚Äëhuman origin;

- blood and its components used for transfusion, germ cells, organs and bone marrow used for transplantation,

and other tissues that do not meet the definition of "medical product";

- in vitro diagnostic devices.

NOTE 4 For guidance on the application of this International Standard, see Annex A.

Previous Editions

Can’t find what you are looking for?

Please contact us at: