ISO 22442:2010
ISO 22442:2010 Medical devices utilizing animal tissues and their derivatives – Part 4: Principles for elimination and/or inactivation of transmissible spongiform encephalopathy (TSE) agents and validation assays for those processes
CDN $192.00
Description
ISO/TR 22442-4:2010 offers suggestions for designing and conducting validation assays to help determine if processes used in the manufacture of medical devices derived from non-viable animal tissues might serve to reduce the risk of iatrogenic transmission of transmissible spongiform encephalopathies (TSEs).
The TSE-removal methods used to process animal tissues should also reduce the risk of transmitting TSE infections via non-viable tissues of human origin; this Technical Report does not address this issue. Some current information on human tissues and TSEs is presented which may be applied by analogy to other animal tissues.
ISO/TR 22442-4:2010 does not intend to imply a need for validation of methods involving specific materials identified as having a “negligible risk” of contamination with TSE agents as listed in Annex C of ISO 22442-1:2007.
It is intended to clarify final draft international standards included in the ISO 22442 series, as well as in ISO 14160.
ISO/TR 22442-4:2010 builds upon the specific discussion in ISO 22442-3 relative to TSE agents and attempts to summarize the current state of the art in the arena of TSE agent elimination. As the understanding of inactivation and elimination of TSE agents evolves, this document will be revised when possible.
Edition
1
Published Date
2010-11-16
Status
PUBLISHED
Pages
14
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
ISO/TR 22442-4:2010 offers suggestions for designing and conducting validation assays to help determine if processes used in the manufacture of medical devices derived from non-viable animal tissues might serve to reduce the risk of iatrogenic transmission of transmissible spongiform encephalopathies (TSEs).
The TSE-removal methods used to process animal tissues should also reduce the risk of transmitting TSE infections via non-viable tissues of human origin; this Technical Report does not address this issue. Some current information on human tissues and TSEs is presented which may be applied by analogy to other animal tissues.
ISO/TR 22442-4:2010 does not intend to imply a need for validation of methods involving specific materials identified as having a "negligible risk" of contamination with TSE agents as listed in Annex C of ISO 22442-1:2007.
It is intended to clarify final draft international standards included in the ISO 22442 series, as well as in ISO 14160.
ISO/TR 22442-4:2010 builds upon the specific discussion in ISO 22442-3 relative to TSE agents and attempts to summarize the current state of the art in the arena of TSE agent elimination. As the understanding of inactivation and elimination of TSE agents evolves, this document will be revised when possible.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 10993:2021 Biological evaluation of medical devices – Part 10: Tests for skin sensitization
CDN $376.00 Add to cart -

ISO 10993:2021 Biological evaluation of medical devices – Part 23: Tests for irritation
CDN $431.00 Add to cart -

ISO 10993:2022 Biological evaluation of medical devices – Part 2: Animal welfare requirements
CDN $192.00 Add to cart -

ISO 17593:2022 Clinical laboratory testing and in vitro medical devices – Requirements for in vitro monitoring systems for self-testing of oral anticoagulant therapy
CDN $391.00 Add to cart