
ISO 16428:2005
ISO 16428:2005 Implants for surgery – Test solutions and environmental conditions for static and dynamic corrosion tests on implantable materials and medical devices
CDN $131.00
Description
ISO 16428:2005 specifies standard environmental conditions for the testing of metallic materials intended for implantation, surgical implants, and medical devices. The testing conditions described simulate physiological conditions in a simplified manner controlling the test solution, the temperature, the gaseous atmosphere and the proportions of sample size and volume of solution.
These environmental testing conditions can be employed where necessary in combination with various static or dynamic tests where the effect of the physiological environment is to be considered. Typical applications are corrosion fatigue tests and selected fretting and wear tests, as well as general electrochemical tests.
Typical articulating joint simulator tests and aspects particular to the dental field are not considered by ISO 16428:2005. Solutions that attempt to replicate the tribological properties of body fluids, such as those used in wear studies, are outside the scope of ISO 16428:2005.
Edition
1
Published Date
2005-04-12
Status
PUBLISHED
Pages
8
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
ISO 16428:2005 specifies standard environmental conditions for the testing of metallic materials intended for implantation, surgical implants, and medical devices. The testing conditions described simulate physiological conditions in a simplified manner controlling the test solution, the temperature, the gaseous atmosphere and the proportions of sample size and volume of solution.
These environmental testing conditions can be employed where necessary in combination with various static or dynamic tests where the effect of the physiological environment is to be considered. Typical applications are corrosion fatigue tests and selected fretting and wear tests, as well as general electrochemical tests.
Typical articulating joint simulator tests and aspects particular to the dental field are not considered by ISO 16428:2005. Solutions that attempt to replicate the tribological properties of body fluids, such as those used in wear studies, are outside the scope of ISO 16428:2005.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 20537:2025 Footwear – Identification of defects during visual inspection – Vocabulary
CDN $310.00 Add to cart -

ISO 16443:2014 Dentistry – Vocabulary for dental implants systems and related procedure
CDN $131.00 Add to cart -

ISO 1990:1982 Fruits – Nomenclature – First list
CDN $131.00 Add to cart -

ISO 13666:2019 Ophthalmic optics – Spectacle lenses – Vocabulary
CDN $86.00 Add to cart







