Search
×
FR

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-6 Chapter 6 – Density

$

204

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 560: Fired Heaters for General Refinery Services

$

721

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 64: Diverter Equipment Systems

$

324

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 17.10.1: Refrigerated Light Hydrocarbon Fluids – Measurement of Cargoes on Board LNG Carries

$

417

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-1: Testing Water-based Drilling Fluids

$

418

BUY NOW

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-12 Chapter 12 – Thermal Conductivity

$

214

BUY NOW

Placeholder headline

This is just a placeholder headline

API 16FI Frac Iron Guidelines and Requirements

$

129

BUY NOW

ISO 3007:1999

ISO 3007:1999 Petroleum products and crude petroleum – Determination of vapour pressure – Reid method

CDN $173.00

Description

This International Standard specifies a method for the determination of the vapour pressure of liquid petroleum

products consisting of essentially or wholly of hydrocarbon components, or containing oxygenated hydrocarbons of

specific types and at specified maximum concentrations. The method does not apply outside these concentration

levels, nor to any blends containing methanol or other oxygenated hydrocarbons not covered in note 1.

NOTE 1 The maximum concentration of ethers containing 5 or more carbon atoms is 15 % (V/V), and for ethanol is 10 %

(V/V). For higher alcohols, the maximum concentration is 7 % (V/V).

NOTE 2 For the purposes of this International Standard, the term “%(V/V)” is used to represent the volume fraction of a

material.

For petroleum products containing methanol, or other oxygenated hydrocarbons outside the scope of note 1, a dry

vapour-pressure test method should be used. For liquefied petroleum gases, ISO 4256 should be used. The test

method may be applied to volatile crude petroleum with a vapour pressure exceeding 10 kPa, although the

precision has not been evaluated.

Four procedures are described in this International Standard. Procedures A and B are alternative apparatus

configurations for products with a Reid vapour pressure up to 180 kPa, Procedure C is applied to liquid products

with a Reid vapour pressure above 180 kPa, and Procedure D applies to aviation gasolines with a Reid vapour

pressure of approximately 50 kPa.

Vapour pressure is an important physical property of volatile liquids, and has critical performance implications for

automotive and aviation gasolines. Vapour pressure is also one of the properties affecting atmospheric evaporation,

and is therefore increasingly used in regulations relating to emissions and air quality control. Vapour pressure is

also a critical property limiting the performance and safety of operation of equipment during transfer operations.

NOTE Because the external atmospheric pressure is counteracted by the atmospheric pressure initially in the vapour

chamber, the Reid vapour pressure is approximately the “absolute” vapour pressure at 37,8 °C. The Reid vapour pressure

differs from the true vapour pressure of the sample owing to slight vaporization of the sample and the pressure of water vapour

and air in the confined space.

Edition

3

Published Date

1999-10-14

Status

PUBLISHED

Pages

17

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This International Standard specifies a method for the determination of the vapour pressure of liquid petroleum

products consisting of essentially or wholly of hydrocarbon components, or containing oxygenated hydrocarbons of

specific types and at specified maximum concentrations. The method does not apply outside these concentration

levels, nor to any blends containing methanol or other oxygenated hydrocarbons not covered in note 1.

NOTE 1 The maximum concentration of ethers containing 5 or more carbon atoms is 15 % (V/V), and for ethanol is 10 %

(V/V). For higher alcohols, the maximum concentration is 7 % (V/V).

NOTE 2 For the purposes of this International Standard, the term "%(V/V)" is used to represent the volume fraction of a

material.

For petroleum products containing methanol, or other oxygenated hydrocarbons outside the scope of note 1, a dry

vapour-pressure test method should be used. For liquefied petroleum gases, ISO 4256 should be used. The test

method may be applied to volatile crude petroleum with a vapour pressure exceeding 10 kPa, although the

precision has not been evaluated.

Four procedures are described in this International Standard. Procedures A and B are alternative apparatus

configurations for products with a Reid vapour pressure up to 180 kPa, Procedure C is applied to liquid products

with a Reid vapour pressure above 180 kPa, and Procedure D applies to aviation gasolines with a Reid vapour

pressure of approximately 50 kPa.

Vapour pressure is an important physical property of volatile liquids, and has critical performance implications for

automotive and aviation gasolines. Vapour pressure is also one of the properties affecting atmospheric evaporation,

and is therefore increasingly used in regulations relating to emissions and air quality control. Vapour pressure is

also a critical property limiting the performance and safety of operation of equipment during transfer operations.

NOTE Because the external atmospheric pressure is counteracted by the atmospheric pressure initially in the vapour

chamber, the Reid vapour pressure is approximately the "absolute" vapour pressure at 37,8 °C. The Reid vapour pressure

differs from the true vapour pressure of the sample owing to slight vaporization of the sample and the pressure of water vapour

and air in the confined space.

Previous Editions

Can’t find what you are looking for?

Please contact us at: