Search
×
FR

Placeholder headline

This is just a placeholder headline

API STD 521: Guide for Pressure-relieving and Depressuring Systems – Edition 6

$

682

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 653: Tank Inspection, Repair, Alteration, and Reconstruction – Edition 4

$

507

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:19 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series-18: Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z246.2-14 – Emergency preparedness and response for petroleum and natural gas industry systems

$

596

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:22 – Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z731-09 (R2014) – Emergency Preparedness and Response

$

177

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:23 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:26 – Storage of Hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA B51:24 Boiler, Pressure Vessel, and Pressure Piping Code

$

389

BUY NOW

ISO 15202:2004

ISO 15202:2004 Workplace air – Determination of metals and metalloids in airborne particulate matter by inductively coupled plasma atomic emission spectrometry – Part 3: Analysis

CDN $336.00

Description

ISO 15202-3:2004 prescribes a procedure for the use of inductively coupled plasma atomic emission spectrometry for analysing test solutions prepared as prescribed in ISO 15202-2 from samples of airborne particulate matter collected as prescribed in ISO 15202-1. Method development, performance checks and a routine analysis method are prescribed.

The procedure suffers from no significant spectral interferences, provided that suitable analytical wavelengths are used. However, inaccurate background correction and/or inadequate matrix-matching can adversely affect results.

ISO 15202-3:2004 is applicable to the following non-exclusive list of metals and metalloids for which limit values have been set; however, there is no information available on the effectiveness of any of the sample dissolution methods specified in ISO 15202-2 for those elements in italics:

aluminium, antimony, arsenic, barium, beryllium, bismuth, boron, caesium, cadmium, calcium, chromium, cobalt, copper, hafnium, indium, iron, lead, lithium, magnesium, manganese, mercury, molybdenum, nickel, phosphorus, platinum, potassium, rhodium, selenium, silver, sodium, strontium, tantalum, tellurium, thallium, tin, titanium, tungsten, uranium, vanadium, yttrium, zinc and zirconium.

ISO 15202-3:2004 is not applicable to determination of elemental mercury, since mercury vapour is not collected using the sampling method specified in ISO 15202-1.

The results obtained may be used for the assessment of workplace exposure to metals and metalloids for comparison with limit values.

Edition

1

Published Date

2004-11-23

Status

PUBLISHED

Pages

37

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO 15202-3:2004 prescribes a procedure for the use of inductively coupled plasma atomic emission spectrometry for analysing test solutions prepared as prescribed in ISO 15202-2 from samples of airborne particulate matter collected as prescribed in ISO 15202-1. Method development, performance checks and a routine analysis method are prescribed.

The procedure suffers from no significant spectral interferences, provided that suitable analytical wavelengths are used. However, inaccurate background correction and/or inadequate matrix-matching can adversely affect results.

ISO 15202-3:2004 is applicable to the following non-exclusive list of metals and metalloids for which limit values have been set; however, there is no information available on the effectiveness of any of the sample dissolution methods specified in ISO 15202-2 for those elements in italics:

aluminium, antimony, arsenic, barium, beryllium, bismuth, boron, caesium, cadmium, calcium, chromium, cobalt, copper, hafnium, indium, iron, lead, lithium, magnesium, manganese, mercury, molybdenum, nickel, phosphorus, platinum, potassium, rhodium, selenium, silver, sodium, strontium, tantalum, tellurium, thallium, tin, titanium, tungsten, uranium, vanadium, yttrium, zinc and zirconium.

ISO 15202-3:2004 is not applicable to determination of elemental mercury, since mercury vapour is not collected using the sampling method specified in ISO 15202-1.

The results obtained may be used for the assessment of workplace exposure to metals and metalloids for comparison with limit values.

Previous Editions

Can’t find what you are looking for?

Please contact us at: