Search
×
FR

Placeholder headline

This is just a placeholder headline

API STD 521: Guide for Pressure-relieving and Depressuring Systems – Edition 6

$

682

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 653: Tank Inspection, Repair, Alteration, and Reconstruction – Edition 4

$

507

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:19 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series-18: Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z246.2-14 – Emergency preparedness and response for petroleum and natural gas industry systems

$

596

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:22 – Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z731-09 (R2014) – Emergency Preparedness and Response

$

177

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:23 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:26 – Storage of Hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA B51:24 Boiler, Pressure Vessel, and Pressure Piping Code

$

389

BUY NOW

ISO 22269:2005

ISO 22269:2005 Reaction to fire tests – Fire growth – Full-scale test for stairs and stair coverings

CDN $186.00

Description

ISO/TS 22269:2005 describes a full-scale reference scenario procedure for assessing the burning behaviour of stairs or stair coverings, when exposed to a defined ignition source. The risks addressed in this scenario are essentially those of a deliberate rather than an accidental fire. The ignition sources specified include a wood crib to represent a local attack with burning crumpled newspaper and a gas burner to represent a more severe attack when the whole width of the bottom step is attacked.

The observations of burning behaviour provide a basis for assessing the fire exposure behaviour of stair coverings installed over different stair substrates.

ISO/TS 22269:2005 is applicable to all types of stair coverings that can be installed on stairs or to the stairs themselves. The results obtained from this method reflect the performance of the total stair covering system together with the stair substrate as tested and are not intended to be the sole criterion for assessing the potential fire hazard of the product in use. Modifications to the stair covering, underlay, fixing system, stair substrate or other changes to the system can affect test results.

Tests are performed with an enclosed or open-sided staircase. In this test method, there is no closure at the top of the stairs to represent a ceiling on a stairs landing. The top of the stairs assembly is open so that the tests are conducted under well-ventilated conditions.

Edition

1

Published Date

2005-11-07

Status

PUBLISHED

Pages

15

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO/TS 22269:2005 describes a full-scale reference scenario procedure for assessing the burning behaviour of stairs or stair coverings, when exposed to a defined ignition source. The risks addressed in this scenario are essentially those of a deliberate rather than an accidental fire. The ignition sources specified include a wood crib to represent a local attack with burning crumpled newspaper and a gas burner to represent a more severe attack when the whole width of the bottom step is attacked.

The observations of burning behaviour provide a basis for assessing the fire exposure behaviour of stair coverings installed over different stair substrates.

ISO/TS 22269:2005 is applicable to all types of stair coverings that can be installed on stairs or to the stairs themselves. The results obtained from this method reflect the performance of the total stair covering system together with the stair substrate as tested and are not intended to be the sole criterion for assessing the potential fire hazard of the product in use. Modifications to the stair covering, underlay, fixing system, stair substrate or other changes to the system can affect test results.

Tests are performed with an enclosed or open-sided staircase. In this test method, there is no closure at the top of the stairs to represent a ceiling on a stairs landing. The top of the stairs assembly is open so that the tests are conducted under well-ventilated conditions.

Previous Editions

Can’t find what you are looking for?

Please contact us at: