Search
×
FR

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-6 Chapter 6 – Density

$

204

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 560: Fired Heaters for General Refinery Services

$

721

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 64: Diverter Equipment Systems

$

324

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 17.10.1: Refrigerated Light Hydrocarbon Fluids – Measurement of Cargoes on Board LNG Carries

$

417

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-1: Testing Water-based Drilling Fluids

$

418

BUY NOW

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-12 Chapter 12 – Thermal Conductivity

$

214

BUY NOW

Placeholder headline

This is just a placeholder headline

API 16FI Frac Iron Guidelines and Requirements

$

129

BUY NOW

ISO 13167:2023

ISO 13167:2023 Water quality – Plutonium, americium, curium and neptunium – Test method using alpha spectrometry

CDN $273.00

SKU: 3dca947d6f67 Categories: , ,

Description

This document specifies a test method for measuring actinides (238Pu, 239+240Pu, 241Am, 242Cm, 243+244Cm and 237Np) in water samples by alpha spectrometry following a chemical separation.

This method can be used for any type of environmental study or monitoring after appropriate sampling and handling, and test sample preparation.

The detection limit of the test method is 5 × 10−3 Bq·l-1 to 5 × 10−4 Bq·l-1 for a volume of test portion between 0,1 l to 5 l with a counting time of two to ten days. This is lower than the WHO criteria for safe consumption of drinking water (1 Bq·l-1 or 10 Bq·l-1 depending on radionuclide).[4]

The method described in this document is applicable in the event of an emergency situation.

Edition

2

Published Date

2023-07-05

Status

PUBLISHED

Pages

29

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies a test method for measuring actinides (238Pu, 239+240Pu, 241Am, 242Cm, 243+244Cm and 237Np) in water samples by alpha spectrometry following a chemical separation.

This method can be used for any type of environmental study or monitoring after appropriate sampling and handling, and test sample preparation.

The detection limit of the test method is 5 × 10−3 Bq·l-1 to 5 × 10−4 Bq·l-1 for a volume of test portion between 0,1 l to 5 l with a counting time of two to ten days. This is lower than the WHO criteria for safe consumption of drinking water (1 Bq·l-1 or 10 Bq·l-1 depending on radionuclide).[4]

The method described in this document is applicable in the event of an emergency situation.

Previous Editions

Can’t find what you are looking for?

Please contact us at: