ISO 17099:2024
ISO 17099:2024 Radiological protection – Performance criteria for laboratories using the cytokinesis-block micronucleus (CBMN) assay in peripheral blood lymphocytes for biological dosimetry
CDN $305.00
Description
This document gives guidance on
a)       confidentiality of personal information for the customer and the laboratory,
b)       laboratory safety requirements,
c)        calibration sources and calibration dose ranges useful for establishing the reference dose-response curves that contribute to the dose estimation from CBMN assay yields and the detection limit,
d)       performance of blood collection, culturing, harvesting, and sample preparation for CBMN assay scoring,
e)       scoring criteria,
f)         conversion of micronucleus frequency in BNCs into an estimate of absorbed dose,
g)       reporting of results,
h)       quality assurance and quality control, and
i)         informative annexes containing sample instructions for customers, sample questionnaire, a microscope scoring data sheet, and a sample report.
This document excludes methods for automated scoring of CBMN.
Edition
2
Published Date
2024-06-14
Status
PUBLISHED
Pages
35
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
This document gives guidance on
a)       confidentiality of personal information for the customer and the laboratory,
b)       laboratory safety requirements,
c)        calibration sources and calibration dose ranges useful for establishing the reference dose-response curves that contribute to the dose estimation from CBMN assay yields and the detection limit,
d)       performance of blood collection, culturing, harvesting, and sample preparation for CBMN assay scoring,
e)       scoring criteria,
f)         conversion of micronucleus frequency in BNCs into an estimate of absorbed dose,
g)       reporting of results,
h)       quality assurance and quality control, and
i)         informative annexes containing sample instructions for customers, sample questionnaire, a microscope scoring data sheet, and a sample report.
This document excludes methods for automated scoring of CBMN.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 20031:2020 Radiological protection – Monitoring and dosimetry for internal exposures due to wound contamination with radionuclides
CDN $305.00 Add to cart -

ISO 12749:2020 Nuclear energy – Vocabulary – Part 1: General terminology
CDN $85.00 Add to cart -

ISO 12749:2018 Nuclear energy, nuclear technologies, and radiological protection – Vocabulary – Part 5: Nuclear reactors
CDN $85.00 Add to cart -

ISO 22908:2020 Water quality – Radium 226 and Radium 228 – Test method using liquid scintillation counting
CDN $305.00 Add to cart