Search
×
FR

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-6 Chapter 6 – Density

$

204

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 560: Fired Heaters for General Refinery Services

$

721

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 64: Diverter Equipment Systems

$

324

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 17.10.1: Refrigerated Light Hydrocarbon Fluids – Measurement of Cargoes on Board LNG Carries

$

417

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-1: Testing Water-based Drilling Fluids

$

418

BUY NOW

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-12 Chapter 12 – Thermal Conductivity

$

214

BUY NOW

Placeholder headline

This is just a placeholder headline

API 16FI Frac Iron Guidelines and Requirements

$

129

BUY NOW

ISO 4723:2023

ISO 4723:2023 Water quality – Actinium-227 – Test method using alpha-spectrometry

CDN $233.00

Description

This document specifies a test method to determine the activity concentration of 227Ac in all types of waters by alpha spectrometry.

The test method is applicable to test samples of supply/drinking water, rainwater, surface and ground water, marine water, as well as cooling water, industrial water, domestic, and industrial wastewater after proper sampling and handling and test sample preparation (see ISO 56671, ISO 56673, ISO 566710). Filtration of the test sample is necessary.

The detection limit depends on the sample volume, the instrument used, the background count rate, the detection efficiency, the counting time, the chemical yield, and the progeny ingrowth. The method described in this document, using currently available alpha spectrometry apparatus, has a detection limit of approximately 0,03 Bq·l−1, when directly measuring the alpha peak of 227Ac. This detection limit is lower than the WHO criteria for safe consumption of drinking water for any actinide alpha emitter (0,1 Bq·l−1).[4] This value can be achieved with a counting time of 48 h for a sample volume of 1 l.

Only a small fraction of 227Ac decays through alpha emissions (~1,42 %). An option to lower the detection limit of the method is to wait, let the progenies of 227Ac grow in, and measure an alpha progeny peak of 227Ac (e.g. 215Po). This is a longer technique, but a lower detection limit of approximately 0,000 2 Bq·l−1 can be obtained by re-counting the sample approximately 90 days after purification. The sample can be re-counted before 90 days, but with a higher detection limit.

The test method(s) described in this document can be used during planned, existing and emergency exposure situations as well as for wastewaters and liquid effluents with specific modifications that can increase the overall uncertainty, detection limit and threshold. For an emergency situation, it is preferable to reduce the counting time rather than the sample volume.

The analysis of 227Ac adsorbed to suspended matter is not covered by this document.

Edition

1

Published Date

2023-11-07

Status

PUBLISHED

Pages

25

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies a test method to determine the activity concentration of 227Ac in all types of waters by alpha spectrometry.

The test method is applicable to test samples of supply/drinking water, rainwater, surface and ground water, marine water, as well as cooling water, industrial water, domestic, and industrial wastewater after proper sampling and handling and test sample preparation (see ISO 5667-1, ISO 5667-3, ISO 5667-10). Filtration of the test sample is necessary.

The detection limit depends on the sample volume, the instrument used, the background count rate, the detection efficiency, the counting time, the chemical yield, and the progeny ingrowth. The method described in this document, using currently available alpha spectrometry apparatus, has a detection limit of approximately 0,03 Bq·l−1, when directly measuring the alpha peak of 227Ac. This detection limit is lower than the WHO criteria for safe consumption of drinking water for any actinide alpha emitter (0,1 Bq·l−1).[4] This value can be achieved with a counting time of 48 h for a sample volume of 1 l.

Only a small fraction of 227Ac decays through alpha emissions (~1,42 %). An option to lower the detection limit of the method is to wait, let the progenies of 227Ac grow in, and measure an alpha progeny peak of 227Ac (e.g. 215Po). This is a longer technique, but a lower detection limit of approximately 0,000 2 Bq·l−1 can be obtained by re-counting the sample approximately 90 days after purification. The sample can be re-counted before 90 days, but with a higher detection limit.

The test method(s) described in this document can be used during planned, existing and emergency exposure situations as well as for wastewaters and liquid effluents with specific modifications that can increase the overall uncertainty, detection limit and threshold. For an emergency situation, it is preferable to reduce the counting time rather than the sample volume.

The analysis of 227Ac adsorbed to suspended matter is not covered by this document.

Previous Editions

Can’t find what you are looking for?

Please contact us at: