REGISTER

FR
Search
×
FR

Placeholder headline

This is just a placeholder headline

API SPEC 14L: Lock Mandrels and Landing Nipples : Reaffirmed

$

273

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 20F: Corrosion Resistant Bolting for Use in the Petroleum and Natural Gas Industries : Reaffirmed

$

169

BUY NOW

Placeholder headline

This is just a placeholder headline

API TR 5NCL Nickel Content Limits for API 5CT Sour Service Products

$

149

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 19ICD: Inflow Control Devices : Reaffirmed

$

189

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 23.2: Reconciliation of Liquid Tank Car(s) Quantities : Reaffirmed

$

218

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 16A: Specification for Drill-through Equipment

$

322

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-2: Field Testing Oil-based Drilling Fluids wA1

$

388

BUY NOW

ISO 4685:2024

ISO 4685:2024 Water quality – Radium 226 – Test method using ICP-MS

CDN $173.00

Description

This document specifies methods to determine 226Ra concentration by inductively coupled plasma mass spectrometry (ICP-MS). The mass concentrations obtained can be converted into activity concentrations.

The method is applicable to test samples of drinking water, rainwater, surface and ground water, after proper sampling and handling, and test sample preparation.

The detection limit depends on the sample volume, the instrument used, the background count rate, the detection efficiency, the counting time and the chemical yield. The detection limit of the method described in this document, using currently available equipment, is approximately 10 mBq·l-1, which is better than the WHO criteria for safe consumption of drinking water (1 Bq·l-1).

This method covers the measurement of 226Ra in water at activity concentrations between 0,001 Bq·l−1 and 100 Bq·l−1. Samples with concentrations higher than 1 Bq·l−1 can be measured if a dilution is performed.

The method described in this document is applicable in the event of an emergency situation.

In this method, filtration of the test sample is necessary. The analysis of 226Ra adsorbed to suspended matter is not covered by this method. The analysis of the insoluble fraction requires a mineralization step that is not covered by this document. In this case, the measurement is made on the different phases obtained.

It is the user’s responsibility to ensure the validity of this test method for the water samples tested.

Edition

1

Published Date

2024-01-09

Status

PUBLISHED

Pages

15

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies methods to determine 226Ra concentration by inductively coupled plasma mass spectrometry (ICP-MS). The mass concentrations obtained can be converted into activity concentrations.

The method is applicable to test samples of drinking water, rainwater, surface and ground water, after proper sampling and handling, and test sample preparation.

The detection limit depends on the sample volume, the instrument used, the background count rate, the detection efficiency, the counting time and the chemical yield. The detection limit of the method described in this document, using currently available equipment, is approximately 10 mBq·l-1, which is better than the WHO criteria for safe consumption of drinking water (1 Bq·l-1).

This method covers the measurement of 226Ra in water at activity concentrations between 0,001 Bq·l−1 and 100 Bq·l−1. Samples with concentrations higher than 1 Bq·l−1 can be measured if a dilution is performed.

The method described in this document is applicable in the event of an emergency situation.

In this method, filtration of the test sample is necessary. The analysis of 226Ra adsorbed to suspended matter is not covered by this method. The analysis of the insoluble fraction requires a mineralization step that is not covered by this document. In this case, the measurement is made on the different phases obtained.

It is the user’s responsibility to ensure the validity of this test method for the water samples tested.

Previous Editions

Can’t find what you are looking for?

Please contact us at: