
ISO 21243:2022
ISO 21243:2022 Radiation protection – Performance criteria for laboratories performing initial cytogenetic dose assessment of mass casualties in radiological or nuclear emergencies – General principles and application to dicentric assay
CDN $173.00
Description
The purpose of this document is to give an overview of the minimum requirements for performing the dicentric assay with quality control measures using mitogen stimulated peripheral blood lymphocytes for initial assessment of individuals involved in a mass casualty scenario. The dicentric assay is the use of chromosome damage to quickly estimate approximate radiation doses received by individuals in order to supplement the early clinical categorization of casualties.
This document focuses on the organizational and operational aspects of applying the dicentric assay in an initial assessment mode. The technical aspects of the dicentric assay can be found in ISO 19238.
This document is applicable either to an experienced biological dosimetry laboratory working alone or to a network of collaborating laboratories (as defined in Clause 7).
Edition
2
Published Date
2022-11-07
Status
PUBLISHED
Pages
18
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
The purpose of this document is to give an overview of the minimum requirements for performing the dicentric assay with quality control measures using mitogen stimulated peripheral blood lymphocytes for initial assessment of individuals involved in a mass casualty scenario. The dicentric assay is the use of chromosome damage to quickly estimate approximate radiation doses received by individuals in order to supplement the early clinical categorization of casualties.
This document focuses on the organizational and operational aspects of applying the dicentric assay in an initial assessment mode. The technical aspects of the dicentric assay can be found in ISO 19238.
This document is applicable either to an experienced biological dosimetry laboratory working alone or to a network of collaborating laboratories (as defined in Clause 7).
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 12749:2018 Nuclear energy, nuclear technologies, and radiological protection – Vocabulary – Part 5: Nuclear reactors
CDN $76.00 Add to cart -

ISO 22908:2020 Water quality – Radium 226 and Radium 228 – Test method using liquid scintillation counting
CDN $273.00 Add to cart -

ISO 8690:2024 Measurement of radioactivity – Gamma ray and beta emitting radionuclides – Test method to assess the ease of decontamination of surface materials
CDN $273.00 Add to cart -

ISO 12749:2015 Nuclear energy, nuclear technologies, and radiological protection – Vocabulary – Part 4: Dosimetry for radiation processing
CDN $273.00 Add to cart







