ISO 22104:2021
ISO 22104:2021 Water quality – Determination of microcystins – Method using liquid chromatography and tandem mass spectrometry (LC-MS/MS)
CDN $305.00
Description
This document specifies a method for the quantification of twelve microcystin variants (microcystin-LR, -LA, -YR, -RR, -LY, -WR, -HtyR, -HilR, -LW, -LF, [Dha7]-microcystin-LR, and [Dha7]-microcystin-RR) in drinking water and freshwater samples between 0,05 µg/l to 1,6 µg/l. The method can be used to determine further microcystins, provided that analytical conditions for chromatography and mass spectrometric detection has been tested and validated for each microcystin. Samples are analysed by LC-MS/MS using internal standard calibration.
This method is performance based. The laboratory is permitted to modify the method, e.g. increasing direct flow injection volume for low interference samples or diluting the samples to increase the upper working range limit, provided that all performance criteria in this method are met.
Detection of microcystins by high resolution mass spectrometry (HRMS) as an alternative for tandem mass spectrometry (MS/MS) is described in Annex A.
An alternative automated sample preparation method based on on-line solid phase extraction coupled to liquid chromatography is described in Annex B.
When instrumental sensitivity is not sufficient to reach the method detection limits by direct flow injection, a solid phase extraction clean-up and concentration step is described in Annex C.
Edition
1
Published Date
2021-07-01
Status
PUBLISHED
Pages
32
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
This document specifies a method for the quantification of twelve microcystin variants (microcystin-LR, -LA, -YR, -RR, -LY, -WR, -HtyR, -HilR, -LW, -LF, [Dha7]-microcystin-LR, and [Dha7]-microcystin-RR) in drinking water and freshwater samples between 0,05 µg/l to 1,6 µg/l. The method can be used to determine further microcystins, provided that analytical conditions for chromatography and mass spectrometric detection has been tested and validated for each microcystin. Samples are analysed by LC-MS/MS using internal standard calibration.
This method is performance based. The laboratory is permitted to modify the method, e.g. increasing direct flow injection volume for low interference samples or diluting the samples to increase the upper working range limit, provided that all performance criteria in this method are met.
Detection of microcystins by high resolution mass spectrometry (HRMS) as an alternative for tandem mass spectrometry (MS/MS) is described in Annex A.
An alternative automated sample preparation method based on on-line solid phase extraction coupled to liquid chromatography is described in Annex B.
When instrumental sensitivity is not sufficient to reach the method detection limits by direct flow injection, a solid phase extraction clean-up and concentration step is described in Annex C.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 9964:1993 Water quality – Determination of sodium and potassium – Part 2: Determination of potassium by atomic absorption spectrometry
CDN $85.00 Add to cart -

ISO 9964:1993 Water quality – Determination of sodium and potassium – Part 3: Determination of sodium and potassium by flame emission spectrometry
CDN $85.00 Add to cart -

ISO 9964:1993 Water quality – Determination of sodium and potassium – Part 1: Determination of sodium by atomic absorption spectrometry
CDN $85.00 Add to cart -

ISO 25101:2009 Water quality – Determination of perfluorooctanesulfonate (PFOS) and perfluorooctanoate (PFOA) – Method for unfiltered samples using solid phase extraction and liquid chromatography/mass spectrometry
CDN $259.00 Add to cart