ISO 28057:2019
ISO 28057:2019 Clinical dosimetry – Dosimetry with solid thermoluminescence detectors for photon and electron radiations in radiotherapy
CDN $336.00
Description
This document describes rules for the procedures, applications, and systems of thermoluminescence dosimetry (TLD) for dose measurements according to the probe method. It is particularly applicable to solid “TL detectors”, i.e. rods, chips, and microcubes, made from LiF:Mg,Ti or LiF:Mg,Cu,P in crystalline or polycrystalline form. It is not applicable to LiF powders because their use requires special procedures. The probe method encompasses the arrangement, particularly in a water phantom or in a tissue-equivalent phantom, of single TL detectors or of “TL probes”, i.e. sets of TL detectors arranged in thin-walled polymethyl methacrylate (PMMA) casings.
The purpose of these rules is to guarantee the reliability and the accuracy indispensable in clinical dosimetry when applied on or in the patient or phantom. This document applies to dosimetry in teletherapy with both photon radiation from 20 keV to 50 MeV and electron radiation from 4 MeV to 25 MeV, as well as in brachytherapy with photon-emitting radionuclides. These applications are complementary to the use of ionization chambers.
Edition
2
Published Date
2019-06-27
Status
PUBLISHED
Pages
41
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
This document describes rules for the procedures, applications, and systems of thermoluminescence dosimetry (TLD) for dose measurements according to the probe method. It is particularly applicable to solid "TL detectors", i.e. rods, chips, and microcubes, made from LiF:Mg,Ti or LiF:Mg,Cu,P in crystalline or polycrystalline form. It is not applicable to LiF powders because their use requires special procedures. The probe method encompasses the arrangement, particularly in a water phantom or in a tissue-equivalent phantom, of single TL detectors or of "TL probes", i.e. sets of TL detectors arranged in thin-walled polymethyl methacrylate (PMMA) casings.
The purpose of these rules is to guarantee the reliability and the accuracy indispensable in clinical dosimetry when applied on or in the patient or phantom. This document applies to dosimetry in teletherapy with both photon radiation from 20 keV to 50 MeV and electron radiation from 4 MeV to 25 MeV, as well as in brachytherapy with photon-emitting radionuclides. These applications are complementary to the use of ionization chambers.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 12749:2020 Nuclear energy, nuclear technologies, and radiological protection – Vocabulary – Part 6: Nuclear medicine
CDN $82.00 Add to cart -

ISO 12749:2015 Nuclear energy, nuclear technologies, and radiological protection – Vocabulary – Part 4: Dosimetry for radiation processing
CDN $295.00 Add to cart -

ISO 22127:2019 Dosimetry with radiophotoluminescent glass dosimeters for dosimetry audit in MV X-ray radiotherapy
CDN $186.00 Add to cart -

ISO 9698:2019 Water quality – Tritium – Test method using liquid scintillation counting
CDN $251.00 Add to cart