ISO 17951:2016
ISO 17951:2016 Water quality – Determination of fluoride using flow analysis (FIA and CFA) – Part 2: Method using continuous flow analysis (CFA) with automated in-line distillation
CDN $173.00
Description
ISO/TS 17951-2:2016 specifies a method for the determination of fluoride in waters, waste waters and effluents by continuous flow analysis (CFA). Any insoluble or complexed fluoride is converted to fluoride ion by an automated continuous flow distillation procedure from sulfuric/phosphoric acid. Fluoride ion in the distillate is measured using flow analysis with lanthanum alizarin complexone and spectrometric detection. This method is applicable to industrial waste waters, effluents, surface waters, ground waters, leachates. When this method is applied to the analysis of drinking water, a heater and a distillation unit is unnecessary. Some drinking water contains high concentration of aluminium and iron. In the case of drinking water, ISO/TS 17951-2:2016 is appropriate to drinking water with low interferences. It is not applicable to samples which contain large amount of suspended matter.
In ISO/TS 17951-2:2016, two working ranges are described:
– working range I: 0,1 mg/l to 1,0 mg/l;
– working range II: 1,0 mg/l to 10 mg/l.
The specification of the calibration solutions are to be adapted accordingly.
Edition
1
Published Date
2016-06-17
Status
PUBLISHED
Pages
16
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
ISO/TS 17951-2:2016 specifies a method for the determination of fluoride in waters, waste waters and effluents by continuous flow analysis (CFA). Any insoluble or complexed fluoride is converted to fluoride ion by an automated continuous flow distillation procedure from sulfuric/phosphoric acid. Fluoride ion in the distillate is measured using flow analysis with lanthanum alizarin complexone and spectrometric detection. This method is applicable to industrial waste waters, effluents, surface waters, ground waters, leachates. When this method is applied to the analysis of drinking water, a heater and a distillation unit is unnecessary. Some drinking water contains high concentration of aluminium and iron. In the case of drinking water, ISO/TS 17951-2:2016 is appropriate to drinking water with low interferences. It is not applicable to samples which contain large amount of suspended matter.
In ISO/TS 17951-2:2016, two working ranges are described:
- working range I: 0,1 mg/l to 1,0 mg/l;
- working range II: 1,0 mg/l to 10 mg/l.
The specification of the calibration solutions are to be adapted accordingly.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 22478:2006 Water quality – Determination of certain explosives and related compounds – Method using high-performance liquid chromatography (HPLC) with UV detection
CDN $233.00 Add to cart -

ISO 20179:2005 Water quality – Determination of microcystins – Method using solid phase extraction (SPE) and high performance liquid chromatography (HPLC) with ultraviolet (UV) detection
CDN $173.00 Add to cart -

ISO 15586:2003 Water quality – Determination of trace elements using atomic absorption spectrometry with graphite furnace
CDN $233.00 Add to cart -

ISO 8467:1993 Water quality – Determination of permanganate index
CDN $76.00 Add to cart