Search
×
FR

Placeholder headline

This is just a placeholder headline

API STD 521: Guide for Pressure-relieving and Depressuring Systems – Edition 6

$

682

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 653: Tank Inspection, Repair, Alteration, and Reconstruction – Edition 4

$

507

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:19 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series-18: Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z246.2-14 – Emergency preparedness and response for petroleum and natural gas industry systems

$

596

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:22 – Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z731-09 (R2014) – Emergency Preparedness and Response

$

177

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:23 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:26 – Storage of Hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA B51:24 Boiler, Pressure Vessel, and Pressure Piping Code

$

389

BUY NOW

ISO 14644:2021

ISO 14644:2021 Cleanrooms and associated controlled environments – Part 17: Particle deposition rate applications

CDN $251.00

SKU: bbaa9e05f7d9 Category:

Description

This document gives direction on the interpretation and application of the results of the measurement of particle deposition rate on one or more vulnerable surfaces in a cleanroom as part of a contamination control programme. It provides some instructions on how to influence the particle deposition rate and reduce the risk of particle contamination on vulnerable surfaces.

This document gives information on how a cleanroom user can use the particle deposition rate measurements to determine limits that can be set for macroparticles on vulnerable surfaces. It also gives a risk assessment method by which an acceptable risk of deposition of particles onto vulnerable surfaces in a cleanroom can be established and, when this is not achieved, methods that can be used to reduce the particle deposition rate.

An alternative to the particle deposition rate is the particle obscuration rate which determines the rate of increase of coverage of particles onto an area of surface over time. The particle obscuration rate can be used in an analogous way to the particle deposition rate and the required particle obscuration rate for a specified surface can be calculated and the risk from deposited particles reduced.

This document does not:

– provide a method to classify a cleanroom with respect to particle deposition rate or particle obscuration rate;

– directly consider the deposition of microbe-carrying particles, although they can be treated as particles;

– give any consideration to surface deposition by contact as, for example, when personnel touch a product and contamination is transferred.

Edition

1

Published Date

2021-02-12

Status

PUBLISHED

Pages

26

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document gives direction on the interpretation and application of the results of the measurement of particle deposition rate on one or more vulnerable surfaces in a cleanroom as part of a contamination control programme. It provides some instructions on how to influence the particle deposition rate and reduce the risk of particle contamination on vulnerable surfaces.

This document gives information on how a cleanroom user can use the particle deposition rate measurements to determine limits that can be set for macroparticles on vulnerable surfaces. It also gives a risk assessment method by which an acceptable risk of deposition of particles onto vulnerable surfaces in a cleanroom can be established and, when this is not achieved, methods that can be used to reduce the particle deposition rate.

An alternative to the particle deposition rate is the particle obscuration rate which determines the rate of increase of coverage of particles onto an area of surface over time. The particle obscuration rate can be used in an analogous way to the particle deposition rate and the required particle obscuration rate for a specified surface can be calculated and the risk from deposited particles reduced.

This document does not:

- provide a method to classify a cleanroom with respect to particle deposition rate or particle obscuration rate;

- directly consider the deposition of microbe-carrying particles, although they can be treated as particles;

- give any consideration to surface deposition by contact as, for example, when personnel touch a product and contamination is transferred.