Search
×
FR

Placeholder headline

This is just a placeholder headline

API MPMS CH 10.8, 3rd Edition: Standard Test Method for Sediment in Crude Oil by Membrane Filtration

$

114

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO/TR 42505:2026 Sharing economy — Shared manufacturing — Concepts and models

$

192

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO 4306-1:2026 Cranes — Vocabulary — Part 1: General

$

436

BUY NOW

ISO 13304:2020

ISO 13304:2020 Radiological protection – Minimum criteria for electron paramagnetic resonance (EPR) spectroscopy for retrospective dosimetry of ionizing radiation – Part 2: Ex vivo human tooth enamel dosimetry

CDN $263.00

SKU: 5627a017a713 Categories: ,

Description

The purpose of this document is to provide minimum criteria required for quality assurance and quality control, evaluation of the performance and to facilitate the comparison of measurements related to absorbed dose estimation obtained in different laboratories applying ex vivo X-band EPR spectroscopy with human tooth enamel.

This document covers the determination of absorbed dose in tooth enamel (hydroxyapatite). It does not cover the calculation of dose to organs or to the body.

This document addresses:

a) responsibilities of the customer and laboratory;

b) confidentiality and ethical considerations;

c) laboratory safety requirements;

d) the measurement apparatus;

e) preparation of samples;

f) measurement of samples and EPR signal evaluation;

g) calibration of EPR dose response;

h) dose uncertainty and performance test;

i) quality assurance and control.

Edition

1

Published Date

2020-07-20

Status

PUBLISHED

Pages

22

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

The purpose of this document is to provide minimum criteria required for quality assurance and quality control, evaluation of the performance and to facilitate the comparison of measurements related to absorbed dose estimation obtained in different laboratories applying ex vivo X-band EPR spectroscopy with human tooth enamel.

This document covers the determination of absorbed dose in tooth enamel (hydroxyapatite). It does not cover the calculation of dose to organs or to the body.

This document addresses:

a) responsibilities of the customer and laboratory;

b) confidentiality and ethical considerations;

c) laboratory safety requirements;

d) the measurement apparatus;

e) preparation of samples;

f) measurement of samples and EPR signal evaluation;

g) calibration of EPR dose response;

h) dose uncertainty and performance test;

i) quality assurance and control.

Previous Editions

Can’t find what you are looking for?

Please contact us at: