Search
×
FR

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-6 Chapter 6 – Density

$

204

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 560: Fired Heaters for General Refinery Services

$

721

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 64: Diverter Equipment Systems

$

324

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 17.10.1: Refrigerated Light Hydrocarbon Fluids – Measurement of Cargoes on Board LNG Carries

$

417

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-1: Testing Water-based Drilling Fluids

$

418

BUY NOW

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-12 Chapter 12 – Thermal Conductivity

$

214

BUY NOW

Placeholder headline

This is just a placeholder headline

API 16FI Frac Iron Guidelines and Requirements

$

129

BUY NOW

ISO 21927:2017

ISO 21927:2017 Smoke and heat control systems – Part 8: Smoke control dampers

CDN $173.00

SKU: 06a5db6950e4 Categories: ,

Description

ISO 21927-8:2017 applies to smoke control dampers, placed on the market and intended to operate as part of a pressure differential system or smoke and heat control system. This document specifies requirements and gives reference to the test methods defined for smoke control dampers and their associated components, such as actuators which are intended to be installed in such systems in buildings. Furthermore, provision on marking and information on installation and maintenance of these products are also given.

ISO 21927-8:2017 distinguishes between two categories of smoke control dampers, i.e. single-compartment smoke control dampers and multi‚Äëcompartment fire-resisting smoke control dampers.

Smoke control dampers covered by this document can be installed into smoke control system ducts or onto the ducts’ surface. They can be installed also into a wall, floor or ceiling/roof elements or onto the surface of these elements.

NOTE To avoid duplication, reference is made to a variety of other standards. To this end, this document can be read in conjunction with EN 13501‚Äë4, EN 1366‚Äë10 and ISO 10294‚Äë1 for details of the furnace testing.

ISO 21927-8:2017 does not consider in detail the detrimental and/or corrosive effects that can be caused by process chemicals present in the atmosphere, which are drawn through the system intentionally or inadvertently.

Edition

1

Published Date

2017-05-02

Status

PUBLISHED

Pages

17

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO 21927-8:2017 applies to smoke control dampers, placed on the market and intended to operate as part of a pressure differential system or smoke and heat control system. This document specifies requirements and gives reference to the test methods defined for smoke control dampers and their associated components, such as actuators which are intended to be installed in such systems in buildings. Furthermore, provision on marking and information on installation and maintenance of these products are also given.

ISO 21927-8:2017 distinguishes between two categories of smoke control dampers, i.e. single-compartment smoke control dampers and multi‚Äëcompartment fire-resisting smoke control dampers.

Smoke control dampers covered by this document can be installed into smoke control system ducts or onto the ducts' surface. They can be installed also into a wall, floor or ceiling/roof elements or onto the surface of these elements.

NOTE To avoid duplication, reference is made to a variety of other standards. To this end, this document can be read in conjunction with EN 13501‚Äë4, EN 1366‚Äë10 and ISO 10294‚Äë1 for details of the furnace testing.