Search
×
FR

Placeholder headline

This is just a placeholder headline

API MPMS CH 10.8, 3rd Edition: Standard Test Method for Sediment in Crude Oil by Membrane Filtration

$

114

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO/TR 42505:2026 Sharing economy — Shared manufacturing — Concepts and models

$

192

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO 4306-1:2026 Cranes — Vocabulary — Part 1: General

$

436

BUY NOW

ISO 7503:2016

ISO 7503:2016 Measurement of radioactivity – Measurement and evaluation of surface contamination – Part 3: Apparatus calibration

CDN $397.00

SKU: 78123fb50579 Category:

Description

ISO 7503 and ISO 8769 are addressed to the people responsible for determining the radioactivity present on solid surfaces.

ISO 7503-3:2016 applies to the evaluation of contamination on surfaces in terms of activity per unit area by direct and indirect methods of measurement and deals with the complex aspects of instrument calibration.

ISO 7503-3:2016 is applicable to well-defined surfaces, such as those of equipment and facilities, containers of radioactive materials, sealed sources, and buildings or land.

ISO 7503-3:2016 can be used for laboratory and equipment/installation control and for remediation and monitoring activities to comply with release criteria.

This part of ISO 7503 also refers to the following:

– calibration laboratories or institutions dealing with radionuclides with complex emission characteristics or radionuclides for which no reference calibration sources are available;

– institutions confronted with the task to evaluate surface contaminations consisting of a radionuclide mixture;

– institutions/authorities controlling nuclear material transports or material/equipment clearance according to national legislation guideline values or international convention limits.

ISO 7503-3:2016 does not apply to contamination of the skin, clothing, or loose material, such as gravel.

NOTE Direct evaluation of surface contamination from alpha-emitters, beta-emitters and photon emitters is dealt with in ISO 7503‚Äë1. The test method using wipe-test samples for the evaluation of radioactive surface contaminations is dealt with in ISO 7503‚Äë2.

Edition

2

Published Date

2016-01-18

Status

PUBLISHED

Pages

64

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO 7503 and ISO 8769 are addressed to the people responsible for determining the radioactivity present on solid surfaces.

ISO 7503-3:2016 applies to the evaluation of contamination on surfaces in terms of activity per unit area by direct and indirect methods of measurement and deals with the complex aspects of instrument calibration.

ISO 7503-3:2016 is applicable to well-defined surfaces, such as those of equipment and facilities, containers of radioactive materials, sealed sources, and buildings or land.

ISO 7503-3:2016 can be used for laboratory and equipment/installation control and for remediation and monitoring activities to comply with release criteria.

This part of ISO 7503 also refers to the following:

- calibration laboratories or institutions dealing with radionuclides with complex emission characteristics or radionuclides for which no reference calibration sources are available;

- institutions confronted with the task to evaluate surface contaminations consisting of a radionuclide mixture;

- institutions/authorities controlling nuclear material transports or material/equipment clearance according to national legislation guideline values or international convention limits.

ISO 7503-3:2016 does not apply to contamination of the skin, clothing, or loose material, such as gravel.

NOTE Direct evaluation of surface contamination from alpha-emitters, beta-emitters and photon emitters is dealt with in ISO 7503‚Äë1. The test method using wipe-test samples for the evaluation of radioactive surface contaminations is dealt with in ISO 7503‚Äë2.

Previous Editions

Can’t find what you are looking for?

Please contact us at: