ISO 14644:2015
ISO 14644:2015 Cleanrooms and associated controlled environments – Part 1: Classification of air cleanliness by particle concentration
CDN $376.00
Description
ISO 14644-1:2015 specifies the classification of air cleanliness in terms of concentration of airborne particles in cleanrooms and clean zones; and separative devices as defined in ISO 14644‚Äë7.
Only particle populations having cumulative distributions based on threshold (lower limit) particle sizes ranging from 0,1 µm to 5 µm are considered for classification purposes.
The use of light scattering (discrete) airborne particle counters (LSAPC) is the basis for determination of the concentration of airborne particles, equal to and greater than the specified sizes, at designated sampling locations.
ISO 14644-1:2015 does not provide for classification of particle populations that are outside the specified lower threshold particle-size range, 0,1 µm to 5 µm. Concentrations of ultrafine particles (particles smaller than 0,1 µm) will be addressed in a separate standard to specify air cleanliness by nano-scale particles. An M descriptor (see Annex C) may be used to quantify populations of macroparticles (particles larger than 5 µm).
ISO 14644-1:2015 cannot be used to characterize the physical, chemical, radiological, viable or other nature of airborne particles.
Edition
2
Published Date
2015-12-09
Status
PUBLISHED
Pages
37
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
ISO 14644-1:2015 specifies the classification of air cleanliness in terms of concentration of airborne particles in cleanrooms and clean zones; and separative devices as defined in ISO 14644‚Äë7.
Only particle populations having cumulative distributions based on threshold (lower limit) particle sizes ranging from 0,1 µm to 5 µm are considered for classification purposes.
The use of light scattering (discrete) airborne particle counters (LSAPC) is the basis for determination of the concentration of airborne particles, equal to and greater than the specified sizes, at designated sampling locations.
ISO 14644-1:2015 does not provide for classification of particle populations that are outside the specified lower threshold particle-size range, 0,1 µm to 5 µm. Concentrations of ultrafine particles (particles smaller than 0,1 µm) will be addressed in a separate standard to specify air cleanliness by nano-scale particles. An M descriptor (see Annex C) may be used to quantify populations of macroparticles (particles larger than 5 µm).
ISO 14644-1:2015 cannot be used to characterize the physical, chemical, radiological, viable or other nature of airborne particles.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 10110:2019 Optics and photonics – Preparation of drawings for optical elements and systems – Part 1: General
CDN $347.00 Add to cart -

ISO 2574:1994 Aircraft – Electrical cables – Identification marking
CDN $129.00 Add to cart -

ISO 5078:2025 Management of terminology resources – Terminology extraction
CDN $259.00 Add to cart -

ISO 80000:2025 Quantities and units – Part 13: Information science and technology
CDN $221.00 Add to cart