Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

ISO 7554-3:2026 Surgical instruments — Terms, measuring methods and test methods — Part 3: Test methods

$

192

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO 41002:2026 Facility management — Development of the facility management organization

$

305

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO 39004:2026 Road traffic safety — Good practice for service providers using digital platform

$

259

BUY NOW

ISO 10295:2009

ISO 10295:2009 Fire tests for building elements and components – Fire testing of service installations – Part 2: Linear joint (gap) seals

CDN $259.00

Description

ISO 10295-2:2009 specifies the heating conditions, methods of test and criteria for the evaluation of the ability of a linear joint seal to maintain the fire integrity and thermal insulation of a fire-separating element at the joint being sealed. The purpose of the tests is to assess the integrity and insulation performance of the linear joint seals, including the effects of induced movement in those cases where the joint is designed to accommodate movement and has a width greater than 20 mm.

It is not the intention of this part of ISO 10295-2:2009 to provide quantitative information on the rate of leakage of smoke and/or gases, or on the transmission or generation of fumes, although such phenomena can be recorded in describing the general behaviour of specimens during the test. It is not the intention of this part of ISO 10295-2:2009 to evaluate joint seals where special test procedures already exist, e.g. doors, partitions, penetrations, pipes, ducts and cables.

Edition

1

Published Date

2009-01-19

Status

PUBLISHED

Pages

24

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO 10295-2:2009 specifies the heating conditions, methods of test and criteria for the evaluation of the ability of a linear joint seal to maintain the fire integrity and thermal insulation of a fire-separating element at the joint being sealed. The purpose of the tests is to assess the integrity and insulation performance of the linear joint seals, including the effects of induced movement in those cases where the joint is designed to accommodate movement and has a width greater than 20 mm.

It is not the intention of this part of ISO 10295-2:2009 to provide quantitative information on the rate of leakage of smoke and/or gases, or on the transmission or generation of fumes, although such phenomena can be recorded in describing the general behaviour of specimens during the test. It is not the intention of this part of ISO 10295-2:2009 to evaluate joint seals where special test procedures already exist, e.g. doors, partitions, penetrations, pipes, ducts and cables.

Previous Editions

Can’t find what you are looking for?

Please contact us at: