Search
×
FR

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-6 Chapter 6 – Density

$

204

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 560: Fired Heaters for General Refinery Services

$

721

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 64: Diverter Equipment Systems

$

324

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 17.10.1: Refrigerated Light Hydrocarbon Fluids – Measurement of Cargoes on Board LNG Carries

$

417

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-1: Testing Water-based Drilling Fluids

$

418

BUY NOW

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-12 Chapter 12 – Thermal Conductivity

$

214

BUY NOW

Placeholder headline

This is just a placeholder headline

API 16FI Frac Iron Guidelines and Requirements

$

129

BUY NOW

ISO 12807:2018

ISO 12807:2018 Safe transport of radioactive materials – Leakage testing on packages

CDN $390.00

SKU: f5d8fac07672 Categories: ,

Description

This document specifies gas leakage test criteria and test methods for demonstrating that packages used to transport radioactive materials comply with the package containment requirements defined in the International Atomic Energy Agency (IAEA) Regulations for the Safe Transport of Radioactive Material for:

– design verification;

– fabrication verification;

– preshipment verification;

– periodic verification;

– maintenance verification.

This document describes a method for relating permissible activity release of the radioactive contents carried within a containment system to equivalent gas leakage rates under specified test conditions. This approach is called gas leakage test methodology. However, in this document it is recognized that other methodologies might be acceptable, provided that they demonstrate that any release of the radioactive contents will not exceed the regulatory requirements, and subject to agreement with the competent authority.

This document provides both overall and detailed guidance on the complex relationships between an equivalent gas leakage test and a permissible activity release rate. Whereas the overall guidance is universally agreed upon, the use of the detailed guidance shall be agreed upon with the competent authority during the Type B(U), Type B(M) or Type C packages certification process.

It should be noted that, for a given package, demonstration of compliance is not limited to a single methodology.

While this document does not require particular gas leakage test procedures, it does present minimum requirements for any test that is to be used. It is the responsibility of the package designer or consignor to estimate or determine the maximum permissible release rate of radioactivity to the environment and to select appropriate leakage test procedures that have adequate sensitivity.

This document pertains specifically to Type B(U), Type B(M) or Type C packages for which the regulatory containment requirements are specified explicitly.

Edition

2

Published Date

2018-09-26

Status

PUBLISHED

Pages

85

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies gas leakage test criteria and test methods for demonstrating that packages used to transport radioactive materials comply with the package containment requirements defined in the International Atomic Energy Agency (IAEA) Regulations for the Safe Transport of Radioactive Material for:

- design verification;

- fabrication verification;

- preshipment verification;

- periodic verification;

- maintenance verification.

This document describes a method for relating permissible activity release of the radioactive contents carried within a containment system to equivalent gas leakage rates under specified test conditions. This approach is called gas leakage test methodology. However, in this document it is recognized that other methodologies might be acceptable, provided that they demonstrate that any release of the radioactive contents will not exceed the regulatory requirements, and subject to agreement with the competent authority.

This document provides both overall and detailed guidance on the complex relationships between an equivalent gas leakage test and a permissible activity release rate. Whereas the overall guidance is universally agreed upon, the use of the detailed guidance shall be agreed upon with the competent authority during the Type B(U), Type B(M) or Type C packages certification process.

It should be noted that, for a given package, demonstration of compliance is not limited to a single methodology.

While this document does not require particular gas leakage test procedures, it does present minimum requirements for any test that is to be used. It is the responsibility of the package designer or consignor to estimate or determine the maximum permissible release rate of radioactivity to the environment and to select appropriate leakage test procedures that have adequate sensitivity.

This document pertains specifically to Type B(U), Type B(M) or Type C packages for which the regulatory containment requirements are specified explicitly.

Previous Editions

Can’t find what you are looking for?

Please contact us at: