ISO 51608:2015
ISO 51608:2015 Practice for dosimetry in an X-ray (bremsstrahlung) facility for radiation processing at energies between 50 keV and 7.5 MeV
CDN $173.00
Description
ISO/ASTM 51608:2015 outlines the dosimetric procedures to be followed during installation qualification, operational qualification, performance qualification and routine processing at an X-ray (bremsstrahlung) irradiator. Other procedures related to operational qualification, performance qualification and routine processing that may influence absorbed dose in the product are also discussed.
ISO/ASTM 51608:2015 is one of a set of standards that provides recommendations for properly implementing and utilizing dosimetry in radiation processing. It is intended to be read in conjunction with ISO/ASTM Practice 52628, “Practice for Dosimetry in Radiation Processing”.
In contrast to monoenergetic gamma radiation, the X-ray energy spectrum extends from low values (about 35 keV) up to the maximum energy of the electrons incident on the X-ray target.
Edition
3
Published Date
2015-03-17
Status
PUBLISHED
Pages
16
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
ISO/ASTM 51608:2015 outlines the dosimetric procedures to be followed during installation qualification, operational qualification, performance qualification and routine processing at an X-ray (bremsstrahlung) irradiator. Other procedures related to operational qualification, performance qualification and routine processing that may influence absorbed dose in the product are also discussed.
ISO/ASTM 51608:2015 is one of a set of standards that provides recommendations for properly implementing and utilizing dosimetry in radiation processing. It is intended to be read in conjunction with ISO/ASTM Practice 52628, "Practice for Dosimetry in Radiation Processing".
In contrast to monoenergetic gamma radiation, the X-ray energy spectrum extends from low values (about 35 keV) up to the maximum energy of the electrons incident on the X-ray target.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 51310:2022 Practice for use of a radiochromic optical waveguide dosimetry system
CDN $76.00 Add to cart -

ISO 52931:2023 Additive manufacturing of metals – Environment, health and safety – General principles for use of metallic materials
CDN $273.00 Add to cart -

ISO 51026:2015 Practice for using the Fricke dosimetry system
CDN $115.00 Add to cart -

ISO 52926:2023 Additive manufacturing of metals – Qualification principles – Part 5: Qualification of operators for DED-Arc
CDN $76.00 Add to cart