ISO 16638:2015
ISO 16638:2015 Radiological protection – Monitoring and internal dosimetry for specific materials – Part 1: Inhalation of uranium compounds
CDN $312.00
Description
ISO 16638-1:2015 specifies the minimum requirements for the design of professional programmes to monitor workers exposed to uranium compounds. It establishes principles for the development of compatible goals and requirements for monitoring programmes and dose assessment for workers occupationally exposed to internal contamination. It establishes procedures and assumptions for risk analysis, monitoring programmes and the standardised interpretation of monitoring data in order to achieve acceptable levels of reliability for uranium and its compounds. It sets limits for the applicability of the procedures in respect to dose levels above which more sophisticated methods have to be applied.
Uranium is both radiologically and chemically toxic. Hence, the scientific bases of current occupational exposure standards are reviewed in addition to radiation exposure limits. This International Standard addresses those circumstances when exposure could be constrained by either radiological or chemical toxicity concerns.
ISO 16638-1:2015 addresses, for uranium and its compounds, the following items:
a) purposes of monitoring and monitoring programmes;
b) description of the different categories of monitoring programmes;
c) quantitative criteria for conducting monitoring programmes;
d) suitable methods for monitoring and criteria for their selection;
e) information that has to be collected for the design of a monitoring programme;
f) general requirements for monitoring programmes (e.g. detection limits, tolerated uncertainties);
g) frequencies of measurements;
h) procedures for dose assessment based on reference levels for routine and special monitoring programmes;
i) assumptions for the selection of dose-critical parameter values;
j) criteria for determining the significance of monitoring results;
k) interpretation of workplace monitoring results;
l) uncertainties arising from dose assessment and interpretation of bioassays data;
m) reporting/documentation;
n) quality assurance;
o) record keeping requirements.
It is not applicable to the following items:
a) monitoring of exposure due to uranium progeny, including radon;
b) detailed descriptions of measuring methods and techniques for uranium;
c) dosimetry for litigation cases;
d) modelling for the improvement of internal dosimetry;
e) potential influence of counter-measures (e.g. administration of chelating agents);
f) investigation of the causes or implications of an exposure;
g) dosimetry for ingestion exposures and for contaminated wounds.
Edition
1
Published Date
2015-12-09
Status
PUBLISHED
Pages
43
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
ISO 16638-1:2015 specifies the minimum requirements for the design of professional programmes to monitor workers exposed to uranium compounds. It establishes principles for the development of compatible goals and requirements for monitoring programmes and dose assessment for workers occupationally exposed to internal contamination. It establishes procedures and assumptions for risk analysis, monitoring programmes and the standardised interpretation of monitoring data in order to achieve acceptable levels of reliability for uranium and its compounds. It sets limits for the applicability of the procedures in respect to dose levels above which more sophisticated methods have to be applied.
Uranium is both radiologically and chemically toxic. Hence, the scientific bases of current occupational exposure standards are reviewed in addition to radiation exposure limits. This International Standard addresses those circumstances when exposure could be constrained by either radiological or chemical toxicity concerns.
ISO 16638-1:2015 addresses, for uranium and its compounds, the following items:
a) purposes of monitoring and monitoring programmes;
b) description of the different categories of monitoring programmes;
c) quantitative criteria for conducting monitoring programmes;
d) suitable methods for monitoring and criteria for their selection;
e) information that has to be collected for the design of a monitoring programme;
f) general requirements for monitoring programmes (e.g. detection limits, tolerated uncertainties);
g) frequencies of measurements;
h) procedures for dose assessment based on reference levels for routine and special monitoring programmes;
i) assumptions for the selection of dose-critical parameter values;
j) criteria for determining the significance of monitoring results;
k) interpretation of workplace monitoring results;
l) uncertainties arising from dose assessment and interpretation of bioassays data;
m) reporting/documentation;
n) quality assurance;
o) record keeping requirements.
It is not applicable to the following items:
a) monitoring of exposure due to uranium progeny, including radon;
b) detailed descriptions of measuring methods and techniques for uranium;
c) dosimetry for litigation cases;
d) modelling for the improvement of internal dosimetry;
e) potential influence of counter-measures (e.g. administration of chelating agents);
f) investigation of the causes or implications of an exposure;
g) dosimetry for ingestion exposures and for contaminated wounds.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 22125:2019 Water quality – Technetium-99 – Part 1: Test method using liquid scintillation counting
CDN $233.00 Add to cart -

ISO 11665:2019 Measurement of radioactivity in the environment – Air: radon-222 – Part 8: Methodologies for initial and additional investigations in buildings
CDN $233.00 Add to cart -

ISO 11704:2018 Water quality – Gross alpha and gross beta activity – Test method using liquid scintillation counting
CDN $233.00 Add to cart -

ISO 11665:2020 Measurement of radioactivity in the environment – Air: radon-222 – Part 6: Spot measurement methods of the activity concentration
CDN $173.00 Add to cart