API MPMS CH 10.8, 3rd Edition: Standard Test Method for Sediment in Crude Oil by Membrane Filtration

$

114

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO/TR 42505:2026 Sharing economy — Shared manufacturing — Concepts and models

$

192

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO 4306-1:2026 Cranes — Vocabulary — Part 1: General

$

436

BUY NOW

ISO 21501:2019

ISO 21501:2019 Determination of particle size distribution – Single particle light interaction methods – Part 3: Light extinction liquid-borne particle counter

CDN $195.00

SKU: f6dbcd57bf8b Categories: ,

Description

This document describes a calibration and verification method for a light extinction liquid-borne particle counter (LELPC), which is used to measure the size and particle number concentration of particles suspended in liquid. The light extinction method described in this document is based on single particle measurements. The typical size range of particles measured by this method is between 1 µm and 100 µm in particle size.

The method is applicable to instruments used for the evaluation of the cleanliness of pharmaceutical products (e.g. injections, water for injections, infusions), as well as the measurement of number and size distribution of particles in various liquids.

The following are within the scope of this document:

– size setting error;

– counting efficiency;

– size resolution;

– maximum particle number concentration;

– sampling flow rate error;

– sampling time error;

– sampling volume error;

– calibration interval;

– reporting results from test and calibration.

Edition

2

Published Date

2019-11-22

Status

PUBLISHED

Pages

18

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document describes a calibration and verification method for a light extinction liquid-borne particle counter (LELPC), which is used to measure the size and particle number concentration of particles suspended in liquid. The light extinction method described in this document is based on single particle measurements. The typical size range of particles measured by this method is between 1 µm and 100 µm in particle size.

The method is applicable to instruments used for the evaluation of the cleanliness of pharmaceutical products (e.g. injections, water for injections, infusions), as well as the measurement of number and size distribution of particles in various liquids.

The following are within the scope of this document:

- size setting error;

- counting efficiency;

- size resolution;

- maximum particle number concentration;

- sampling flow rate error;

- sampling time error;

- sampling volume error;

- calibration interval;

- reporting results from test and calibration.