ISO 18563:2024

ISO 18563:2024 Non-destructive testing – Characterization and verification of ultrasonic phased array equipment – Part 2: Array probes

CDN $129.00

SKU: 0f2fe0a00ffc Categories: ,

Description

This document specifies characterization tests to be performed at the end of the fabrication of an array probe. It defines both methodology and acceptance criteria.

This document is applicable to the following array probes used for ultrasonic non-destructive testing [phased array technique or signal processing technique, e.g. full-matrix capture (FMC) and total-focusing technique (TFM)] in contact technique (with or without a wedge or delay line) or in immersion technique, with centre frequencies in the range 0,5 MHz to 10 MHz:

a)       array probes with elements in one direction:

    1-D-linear array (linear array);

    1-D-curved array;

    annular array;

b)       array probes with elements in two directions:

    2-D-array (matrix array);

    sectorial annular array;

    partial sectorial annular array.

This document does not give methods and acceptance criteria to characterize the performance of an ultrasonic phased array instrument or the performance of a complete system, which are given in ISO 18563–1 and in ISO 18563–3.

Edition

2

Published Date

2024-09-24

Status

PUBLISHED

Pages

10

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies characterization tests to be performed at the end of the fabrication of an array probe. It defines both methodology and acceptance criteria.

This document is applicable to the following array probes used for ultrasonic non-destructive testing [phased array technique or signal processing technique, e.g. full-matrix capture (FMC) and total-focusing technique (TFM)] in contact technique (with or without a wedge or delay line) or in immersion technique, with centre frequencies in the range 0,5 MHz to 10 MHz:

a)       array probes with elements in one direction:

-    1-D-linear array (linear array);

-    1-D-curved array;

-    annular array;

b)       array probes with elements in two directions:

-    2-D-array (matrix array);

-    sectorial annular array;

-    partial sectorial annular array.

This document does not give methods and acceptance criteria to characterize the performance of an ultrasonic phased array instrument or the performance of a complete system, which are given in ISO 18563–1 and in ISO 18563–3.