
ISO 18563:2024
ISO 18563:2024 Non-destructive testing – Characterization and verification of ultrasonic phased array equipment – Part 2: Array probes
CDN $124.00
Description
This document specifies characterization tests to be performed at the end of the fabrication of an array probe. It defines both methodology and acceptance criteria.
This document is applicable to the following array probes used for ultrasonic non-destructive testing [phased array technique or signal processing technique, e.g. full-matrix capture (FMC) and total-focusing technique (TFM)] in contact technique (with or without a wedge or delay line) or in immersion technique, with centre frequencies in the range 0,5 MHz to 10 MHz:
a)       array probes with elements in one direction:
–¬†¬†¬† 1-D-linear array (linear array);
–¬†¬†¬† 1-D-curved array;
–¬†¬†¬† annular array;
b)       array probes with elements in two directions:
–¬†¬†¬† 2-D-array (matrix array);
–¬†¬†¬† sectorial annular array;
–¬†¬†¬† partial sectorial annular array.
This document does not give methods and acceptance criteria to characterize the performance of an ultrasonic phased array instrument or the performance of a complete system, which are given in ISO 18563–1 and in ISO 18563–3.
Edition
2
Published Date
2024-09-24
Status
PUBLISHED
Pages
10
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
This document specifies characterization tests to be performed at the end of the fabrication of an array probe. It defines both methodology and acceptance criteria.
This document is applicable to the following array probes used for ultrasonic non-destructive testing [phased array technique or signal processing technique, e.g. full-matrix capture (FMC) and total-focusing technique (TFM)] in contact technique (with or without a wedge or delay line) or in immersion technique, with centre frequencies in the range 0,5 MHz to 10 MHz:
a)       array probes with elements in one direction:
-    1-D-linear array (linear array);
-    1-D-curved array;
-    annular array;
b)       array probes with elements in two directions:
-    2-D-array (matrix array);
-    sectorial annular array;
-    partial sectorial annular array.
This document does not give methods and acceptance criteria to characterize the performance of an ultrasonic phased array instrument or the performance of a complete system, which are given in ISO 18563–1 and in ISO 18563–3.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 20537:2025 Footwear – Identification of defects during visual inspection – Vocabulary
CDN $295.00 Add to cart -

ISO 22553:2019 Paints and varnishes – Electro-deposition coatings – Part 1: Vocabulary
CDN $82.00 Add to cart -

ISO 80004:2011 Nanotechnologies – Vocabulary – Part 5: Nano/bio interface
CDN $82.00 Add to cart -

ISO 1176:1990 Road vehicles – Masses – Vocabulary and codes
CDN $124.00 Add to cart







