ISO 32543:2024
ISO 32543:2024 Non-destructive testing – Characteristics of focal spots in industrial X-ray systems – Part 1: Pinhole camera radiographic method
CDN $173.00
Description
This document specifies a method for the measurement of effective focal spot dimensions above 0,1 mm of X-ray systems up to and including 1 000 kV X-ray voltage by means of the pinhole camera method with digital evaluation. The tube voltage applied for this measurement is restricted to 200 kV for visual film evaluation and can be selected higher than 200 kV if digital detectors are used.
The imaging quality and the resolution of X-ray images depend highly on the characteristics of the effective focal spot, in particular the size and the two-dimensional intensity distribution as seen from the detector plane. Compared to the other methods specified in the EN 12543 series and the ISO 32543 series, this method allows to obtain an image of the focal spot and to see the state of it (e.g. cratering of the anode).
This test method provides instructions for determining the effective size (dimensions) of standard (macro focal spots) and mini focal spots of industrial X-ray tubes. This determination is based on the measurement of an image of a focal spot that has been radiographically recorded with a “pinhole” technique and evaluated with a digital method.
For the characterization of commercial X-ray tube types (i.e. for advertising or trade), the specific FS (focal spot) values of Annex A can be used.
Edition
1
Published Date
2024-05-03
Status
PUBLISHED
Pages
15
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
This document specifies a method for the measurement of effective focal spot dimensions above 0,1 mm of X-ray systems up to and including 1 000 kV X-ray voltage by means of the pinhole camera method with digital evaluation. The tube voltage applied for this measurement is restricted to 200 kV for visual film evaluation and can be selected higher than 200 kV if digital detectors are used.
The imaging quality and the resolution of X-ray images depend highly on the characteristics of the effective focal spot, in particular the size and the two-dimensional intensity distribution as seen from the detector plane. Compared to the other methods specified in the EN 12543 series and the ISO 32543 series, this method allows to obtain an image of the focal spot and to see the state of it (e.g. cratering of the anode).
This test method provides instructions for determining the effective size (dimensions) of standard (macro focal spots) and mini focal spots of industrial X-ray tubes. This determination is based on the measurement of an image of a focal spot that has been radiographically recorded with a “pinhole” technique and evaluated with a digital method.
For the characterization of commercial X-ray tube types (i.e. for advertising or trade), the specific FS (focal spot) values of Annex A can be used.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 16838:2019 Non-destructive testing – Acoustic emission testing – Test method for classification of active cracks in concrete structures
CDN $76.00 Add to cart -

ISO 10878:2013 Non-destructive testing – Infrared thermography – Vocabulary
CDN $273.00 Add to cart -

ISO 5577:2017 Non-destructive testing – Ultrasonic testing – Vocabulary
CDN $76.00 Add to cart -

ISO 18490:2015 Non-destructive testing – Evaluation of vision acuity of NDT personnel
CDN $115.00 Add to cart