Search
×
FR

Placeholder headline

This is just a placeholder headline

API STD 521: Guide for Pressure-relieving and Depressuring Systems – Edition 6

$

682

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 653: Tank Inspection, Repair, Alteration, and Reconstruction – Edition 4

$

507

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:19 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series-18: Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z246.2-14 – Emergency preparedness and response for petroleum and natural gas industry systems

$

596

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:22 – Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z731-09 (R2014) – Emergency Preparedness and Response

$

177

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:23 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:26 – Storage of Hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA B51:24 Boiler, Pressure Vessel, and Pressure Piping Code

$

389

BUY NOW

ISO 22232:2020

ISO 22232:2020 Non-destructive testing – Characterization and verification of ultrasonic test equipment – Part 2: Probes

CDN $379.00

SKU: 1a917ccbfcde Category:

Description

This document specifies the characteristics of probes used for non-destructive ultrasonic testing in the following categories with centre frequencies in the range of 0,5 MHz to 15 MHz, focusing or without focusing means:

a) single- or dual-transducer contact probes generating longitudinal and/or transverse waves;

b) single-transducer immersion probes.

Where material-dependent ultrasonic values are specified in this document they are based on steels having a sound velocity of (5 920 ± 50) m/s for longitudinal waves, and (3 255 ± 30) m/s for transverse waves.

This document excludes periodic tests for probes. Routine tests for the verification of probes using on-site procedures are given in ISO 22232-3.

If parameters in addition to those specified in ISO 22232-3 are to be verified during the probe’s life time, as agreed upon by the contracting parties, the procedures of verification for these additional parameters can be selected from those given in this document.

This document also excludes ultrasonic phased array probes, therefore see ISO 18563-2.

Edition

1

Published Date

2020-09-18

Status

PUBLISHED

Pages

56

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies the characteristics of probes used for non-destructive ultrasonic testing in the following categories with centre frequencies in the range of 0,5 MHz to 15 MHz, focusing or without focusing means:

a) single- or dual-transducer contact probes generating longitudinal and/or transverse waves;

b) single-transducer immersion probes.

Where material-dependent ultrasonic values are specified in this document they are based on steels having a sound velocity of (5 920 ± 50) m/s for longitudinal waves, and (3 255 ± 30) m/s for transverse waves.

This document excludes periodic tests for probes. Routine tests for the verification of probes using on-site procedures are given in ISO 22232-3.

If parameters in addition to those specified in ISO 22232-3 are to be verified during the probe's life time, as agreed upon by the contracting parties, the procedures of verification for these additional parameters can be selected from those given in this document.

This document also excludes ultrasonic phased array probes, therefore see ISO 18563-2.

Previous Editions

Can’t find what you are looking for?

Please contact us at: