Search
×
FR

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-6 Chapter 6 – Density

$

204

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 560: Fired Heaters for General Refinery Services

$

721

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 64: Diverter Equipment Systems

$

324

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 17.10.1: Refrigerated Light Hydrocarbon Fluids – Measurement of Cargoes on Board LNG Carries

$

417

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-1: Testing Water-based Drilling Fluids

$

418

BUY NOW

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-12 Chapter 12 – Thermal Conductivity

$

214

BUY NOW

Placeholder headline

This is just a placeholder headline

API 16FI Frac Iron Guidelines and Requirements

$

129

BUY NOW

ISO 15724:2001

ISO 15724:2001 Metallic and other inorganic coatings – Electrochemical measurement of diffusible hydrogen in steels – Barnacle electrode method

CDN $115.00

SKU: 3d158aca91b0 Category:

Description

This International Standard describes a method that uses an electronic hydrogen detection instrument for measuring

relative, diffusible hydrogen concentrations in bare steels or in plated steels after the coating has been removed. It is

assumed that the hydrogen is uniformly distributed throughout a part.

The method does not measure actual hydrogen concentration. However, oxidation current densities measured

against time provide a useful indication of relative hydrogen concentrations and, therefore, the measurements can be

used for comparison purposes. The method may be used as a quality control procedure as it does provide a quick

means of measuring the effectiveness of pre- and/or post-plating heat treatments or of monitoring hydrogen uptake

during plating or due to corrosion.

It is important to note that the absence of failure in a particular test does not provide confirmation of complete

elimination of hydrogen embrittlement because no one test method can provide all the data necessary to evaluate

the degree of hydrogen degradation.

For unplated parts the method is non-destructive; however, for plated parts the coating has to be removed prior to

measurement by a means proven not to damage the steel or to introduce hydrogen.

This test method is limited to:

– carbon and alloy steels, excluding austenitic stainless steels (see note 1);

– flat specimens to which the cell can be attached (see note 2);

– measurements at room temperature ( ).

NOTE 1 If this method is used for austenitic stainless steels and other face centred cubic (FCC) alloys, measurement times and

interpretation of results will have to be determined because of the different kinetics involved.

NOTE 2 For slightly curved surfaces it is essential to define an area that is reproducible. The area calculation will be different

from that described in this International Standard.

NOTE 3 The method can be applied to small parts, however, this necessitates some modification of the technique, procedure

and interpretation of results.

Edition

1

Published Date

2001-12-13

Status

PUBLISHED

Pages

10

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This International Standard describes a method that uses an electronic hydrogen detection instrument for measuring

relative, diffusible hydrogen concentrations in bare steels or in plated steels after the coating has been removed. It is

assumed that the hydrogen is uniformly distributed throughout a part.

The method does not measure actual hydrogen concentration. However, oxidation current densities measured

against time provide a useful indication of relative hydrogen concentrations and, therefore, the measurements can be

used for comparison purposes. The method may be used as a quality control procedure as it does provide a quick

means of measuring the effectiveness of pre- and/or post-plating heat treatments or of monitoring hydrogen uptake

during plating or due to corrosion.

It is important to note that the absence of failure in a particular test does not provide confirmation of complete

elimination of hydrogen embrittlement because no one test method can provide all the data necessary to evaluate

the degree of hydrogen degradation.

For unplated parts the method is non-destructive; however, for plated parts the coating has to be removed prior to

measurement by a means proven not to damage the steel or to introduce hydrogen.

This test method is limited to:

- carbon and alloy steels, excluding austenitic stainless steels (see note 1);

- flat specimens to which the cell can be attached (see note 2);

- measurements at room temperature ( ).

NOTE 1 If this method is used for austenitic stainless steels and other face centred cubic (FCC) alloys, measurement times and

interpretation of results will have to be determined because of the different kinetics involved.

NOTE 2 For slightly curved surfaces it is essential to define an area that is reproducible. The area calculation will be different

from that described in this International Standard.

NOTE 3 The method can be applied to small parts, however, this necessitates some modification of the technique, procedure

and interpretation of results.