ISO 80079:2016
ISO 80079:2016 Explosive atmospheres – Part 37: Non-electrical equipment for explosive atmospheres – Non-electrical type of protection constructional safety ”c”, control of ignition sources ”b”, liquid immersion ”k”
CDN $422.00
Description
ISO 80079-37:2016 specifies the requirements for the design and construction of non-electrical equipment, intended for use in explosive atmospheres, protected by the types of protection
constructional safety “c”, control of ignition source “b” and liquid immersion “k”. This part of ISO/IEC 80079 supplements and modifies the requirements in ISO 80079-36. Where a requirement of this standard conflicts with the requirement of ISO 80079-36 the requirement of this standard takes precedence. Types of protection “c”, “k” and “b” are not applicable for Group I, EPL Ma without
additional protective precautions. The types of ignition protection described in the standard can be used either on their own or in combination with each other to meet the requirements for equipment of Group I, Group II, and Group III depending on the ignition hazard assessment in ISO 80079-36.
Keywords: constructional safety “c”, control of ignition source “b” and liquid immersion “k”
Edition
1
Published Date
2016-03-09
Status
PUBLISHED
Pages
91
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
ISO 80079-37:2016 specifies the requirements for the design and construction of non-electrical equipment, intended for use in explosive atmospheres, protected by the types of protection constructional safety "c", control of ignition source "b" and liquid immersion "k". This part of ISO/IEC 80079 supplements and modifies the requirements in ISO 80079-36. Where a requirement of this standard conflicts with the requirement of ISO 80079-36 the requirement of this standard takes precedence. Types of protection "c", "k" and "b" are not applicable for Group I, EPL Ma without additional protective precautions. The types of ignition protection described in the standard can be used either on their own or in combination with each other to meet the requirements for equipment of Group I, Group II, and Group III depending on the ignition hazard assessment in ISO 80079-36. Keywords: constructional safety "c", control of ignition source "b" and liquid immersion "k"
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 10807:1994 Pipework – Corrugated flexible metallic hose assemblies for the protection of electrical cables in explosive atmospheres
CDN $124.00 Add to cart -

ISO 80079:2018 Explosive atmospheres – Part 34: Application of quality management systems for Ex Product manufacture
CDN $422.00 Add to cart -

ISO 80079:2016 Explosive atmospheres – Part 20-2: Material characteristics – Combustible dusts test methods
CDN $422.00 Add to cart -

ISO 80079:2017 Explosive atmospheres – Part 20-1: Material characteristics for gas and vapour classification – Test methods and data
CDN $422.00 Add to cart