Search
×
FR

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-6 Chapter 6 – Density

$

204

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 560: Fired Heaters for General Refinery Services

$

721

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 64: Diverter Equipment Systems

$

324

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 17.10.1: Refrigerated Light Hydrocarbon Fluids – Measurement of Cargoes on Board LNG Carries

$

417

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-1: Testing Water-based Drilling Fluids

$

418

BUY NOW

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-12 Chapter 12 – Thermal Conductivity

$

214

BUY NOW

Placeholder headline

This is just a placeholder headline

API 16FI Frac Iron Guidelines and Requirements

$

129

BUY NOW

ISO 15632:2021

ISO 15632:2021 Microbeam analysis – Selected instrumental performance parameters for the specification and checking of energy-dispersive X-ray spectrometers (EDS) for use with a scanning electron microscope (SEM) or an electron probe microanalyser (EPMA)

CDN $173.00

SKU: a0ed2cab9ba6 Category:

Description

This document defines the most important quantities that characterize an energy-dispersive X‚Äëray spectrometer consisting of a semiconductor detector, a pre-amplifier and a signal-processing unit as the essential parts. This document is only applicable to spectrometers with semiconductor detectors operating on the principle of solid-state ionization. This document specifies minimum requirements and how relevant instrumental performance parameters are to be checked for such spectrometers attached to a scanning electron microscope (SEM) or an electron probe microanalyser (EPMA). The procedure used for the actual analysis is outlined in ISO 22309[2] and ASTM E1508[3] and is outside the scope of this document.

Edition

3

Published Date

2021-02-12

Status

PUBLISHED

Pages

13

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document defines the most important quantities that characterize an energy-dispersive X‚Äëray spectrometer consisting of a semiconductor detector, a pre-amplifier and a signal-processing unit as the essential parts. This document is only applicable to spectrometers with semiconductor detectors operating on the principle of solid-state ionization. This document specifies minimum requirements and how relevant instrumental performance parameters are to be checked for such spectrometers attached to a scanning electron microscope (SEM) or an electron probe microanalyser (EPMA). The procedure used for the actual analysis is outlined in ISO 22309[2] and ASTM E1508[3] and is outside the scope of this document.

Previous Editions

Can’t find what you are looking for?

Please contact us at: