
ISO 25498:2018
ISO 25498:2018 Microbeam analysis – Analytical electron microscopy – Selected area electron diffraction analysis using a transmission electron microscope
CDN $336.00
Description
ISO 25498:2018 specifies the method of selected area electron diffraction (SAED) analysis using a transmission electron microscope (TEM) to analyse thin crystalline specimens. This document applies to test areas of micrometres and sub-micrometres in size. The minimum diameter of the selected area in a specimen which can be analysed by this method is restricted by the spherical aberration coefficient of the objective lens of the microscope and approaches several hundred nanometres for a modern TEM.
When the size of an analysed specimen area is smaller than that restriction, this document can also be used for the analysis procedure. But, because of the effect of spherical aberration, some of the diffraction information in the pattern can be generated from outside of the area defined by the selected area aperture. In such cases, the use of microdiffraction (nano-beam diffraction) or convergent beam electron diffraction, where available, might be preferred.
ISO 25498:2018 is applicable to the acquisition of SAED patterns from crystalline specimens, indexing the patterns and calibration of the diffraction constant.
Edition
2
Published Date
2018-03-16
Status
PUBLISHED
Pages
38
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
ISO 25498:2018 specifies the method of selected area electron diffraction (SAED) analysis using a transmission electron microscope (TEM) to analyse thin crystalline specimens. This document applies to test areas of micrometres and sub-micrometres in size. The minimum diameter of the selected area in a specimen which can be analysed by this method is restricted by the spherical aberration coefficient of the objective lens of the microscope and approaches several hundred nanometres for a modern TEM.
When the size of an analysed specimen area is smaller than that restriction, this document can also be used for the analysis procedure. But, because of the effect of spherical aberration, some of the diffraction information in the pattern can be generated from outside of the area defined by the selected area aperture. In such cases, the use of microdiffraction (nano-beam diffraction) or convergent beam electron diffraction, where available, might be preferred.
ISO 25498:2018 is applicable to the acquisition of SAED patterns from crystalline specimens, indexing the patterns and calibration of the diffraction constant.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 8927:1991 Earth-moving machinery – Machine availability – Vocabulary
CDN $263.00 Add to cart -

ISO 612:1978 Road vehicles – Dimensions of motor vehicles and towed vehicles – Terms and definitions
CDN $195.00 Add to cart -

ISO 8384:2019 Ships and marine technology – Dredgers – Vocabulary
CDN $86.00 Add to cart -

ISO 2382:2015 Information technology – Vocabulary
CDN $0.00 Add to cart







