Search
×
FR

Placeholder headline

This is just a placeholder headline

API STD 521: Guide for Pressure-relieving and Depressuring Systems – Edition 6

$

682

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 653: Tank Inspection, Repair, Alteration, and Reconstruction – Edition 4

$

507

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:19 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series-18: Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z246.2-14 – Emergency preparedness and response for petroleum and natural gas industry systems

$

596

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:22 – Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z731-09 (R2014) – Emergency Preparedness and Response

$

177

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:23 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:26 – Storage of Hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA B51:24 Boiler, Pressure Vessel, and Pressure Piping Code

$

389

BUY NOW

ISO 10292:1994

ISO 10292:1994 Glass in building – Calculation of steady-state U values (thermal transmittance) of multiple glazing

CDN $124.00

Description

Applies to glass, coated glass and materials opaque in the far infrared wavelengths. Gives the fundamental rules for calculating the thermal transmittance in the glazing central area (edge effects are not included). The rules are intended to enable the heat loss through glazing in a building to be estimated from the U values and, together with heat losses through the opaque elements of the building, are used to determine the capacity of the heating or cooling plant. In addition, U values for other purposes (e.g. condensation on glazing surfaces, seasonal heat loss through glazing) can be calculated using the same procedure.

Edition

1

Published Date

1994-06-30

Status

PUBLISHED

Pages

8

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Applies to glass, coated glass and materials opaque in the far infrared wavelengths. Gives the fundamental rules for calculating the thermal transmittance in the glazing central area (edge effects are not included). The rules are intended to enable the heat loss through glazing in a building to be estimated from the U values and, together with heat losses through the opaque elements of the building, are used to determine the capacity of the heating or cooling plant. In addition, U values for other purposes (e.g. condensation on glazing surfaces, seasonal heat loss through glazing) can be calculated using the same procedure.

Previous Editions

Can’t find what you are looking for?

Please contact us at: