Search
×
FR

Placeholder headline

This is just a placeholder headline

API STD 521: Guide for Pressure-relieving and Depressuring Systems – Edition 6

$

682

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 653: Tank Inspection, Repair, Alteration, and Reconstruction – Edition 4

$

507

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:19 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series-18: Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z246.2-14 – Emergency preparedness and response for petroleum and natural gas industry systems

$

596

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:22 – Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z731-09 (R2014) – Emergency Preparedness and Response

$

177

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:23 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:26 – Storage of Hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA B51:24 Boiler, Pressure Vessel, and Pressure Piping Code

$

389

BUY NOW

ISO 13129:2012

ISO 13129:2012 Paints and varnishes – Electrochemical measurement of the protection provided to steel by paint coatings – Current interrupter (CI) technique, relaxation voltammetry (RV) technique and DC transient (DCT) measurements

CDN $186.00

SKU: a3a26d16ef09 Category:

Description

1 Scope

This International Standard specifies the procedure for evaluation of the experimental set-up of electrochemical

measurements on high-impedance coated samples using methods that are based on the current interrupter

(CI) technique, relaxation voltammetry (RV) or DC transient (DCT) measurements.

It provides specific definitions and guidance on optimizing the collection of CI, RV and DCT data from highimpedance

systems. High impedance in the context of intact coatings refers to systems with an impedance

greater than 109 Ω/cm2. This does not preclude measurements on systems with lower impedance. This

International Standard deals in particular with:

– instrumental set-up: requirements and shortcomings;

– data validation: checking the measurement range and the accuracy of the data;

– performing CI, RV, DCT measurements: specimen considerations and instrumental parameters;

– the experimental results: different methods of presenting CI, RV and DCT data.

Following the recommendations should ensure the acquisition of CI, RV and DCT data that can be used to study the

performance of the specimen. This International Standard does not give guidelines for the interpretation of the data.

Edition

1

Published Date

2012-09-24

Status

PUBLISHED

Pages

15

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

1 Scope

This International Standard specifies the procedure for evaluation of the experimental set-up of electrochemical

measurements on high-impedance coated samples using methods that are based on the current interrupter

(CI) technique, relaxation voltammetry (RV) or DC transient (DCT) measurements.

It provides specific definitions and guidance on optimizing the collection of CI, RV and DCT data from highimpedance

systems. High impedance in the context of intact coatings refers to systems with an impedance

greater than 109 Ω/cm2. This does not preclude measurements on systems with lower impedance. This

International Standard deals in particular with:

- instrumental set-up: requirements and shortcomings;

- data validation: checking the measurement range and the accuracy of the data;

- performing CI, RV, DCT measurements: specimen considerations and instrumental parameters;

- the experimental results: different methods of presenting CI, RV and DCT data.

Following the recommendations should ensure the acquisition of CI, RV and DCT data that can be used to study the

performance of the specimen. This International Standard does not give guidelines for the interpretation of the data.

Previous Editions

Can’t find what you are looking for?

Please contact us at: