Search
×
FR

Placeholder headline

This is just a placeholder headline

API STD 521: Guide for Pressure-relieving and Depressuring Systems – Edition 6

$

682

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 653: Tank Inspection, Repair, Alteration, and Reconstruction – Edition 4

$

507

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:19 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series-18: Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z246.2-14 – Emergency preparedness and response for petroleum and natural gas industry systems

$

596

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:22 – Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z731-09 (R2014) – Emergency Preparedness and Response

$

177

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:23 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:26 – Storage of Hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA B51:24 Boiler, Pressure Vessel, and Pressure Piping Code

$

389

BUY NOW

ISO 15181:2008

ISO 15181:2008 Paints and varnishes – Determination of release rate of biocides from antifouling paints – Part 4: Determination of pyridine-triphenylborane (PTPB) concentration in the extract and calculation of the release rate

CDN $124.00

SKU: 5ad014435a1d Category:

Description

ISO 15181-4:2008 specifies the apparatus and analytical method for determining the amount of pyridine-triphenylborane (PTPB) that has been released from an antifouling paint into artificial seawater in accordance with the procedure given in ISO 15181‚Äë1. It determines the PTPB concentration in the artificial seawater extract and gives the final calculation for the release rate of PTPB under the specified laboratory conditions.

This part of ISO 15181 is designed to allow the concurrent determination of PTPB and other biocides that can be released by a given antifouling paint (for example, zineb) through the analysis of separate sub-samples of an artificial seawater extract generated in accordance with the procedure given in ISO 15181‚Äë1.

When used in conjunction with ISO 15181‚Äë1, the practical limits on the quantitative measurement of release rates by this method are from 1,8 micrograms per square centimetre per day to 500 micrograms per square centimetre per day. The quantitative measurement of release rates below this range will require an additional concentration step described in the text or the use of an analytical method with a lower limit of quantitation for PTPB in artificial seawater.

Edition

1

Published Date

2008-07-23

Status

PUBLISHED

Pages

12

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO 15181-4:2008 specifies the apparatus and analytical method for determining the amount of pyridine-triphenylborane (PTPB) that has been released from an antifouling paint into artificial seawater in accordance with the procedure given in ISO 15181‚Äë1. It determines the PTPB concentration in the artificial seawater extract and gives the final calculation for the release rate of PTPB under the specified laboratory conditions.

This part of ISO 15181 is designed to allow the concurrent determination of PTPB and other biocides that can be released by a given antifouling paint (for example, zineb) through the analysis of separate sub-samples of an artificial seawater extract generated in accordance with the procedure given in ISO 15181‚Äë1.

When used in conjunction with ISO 15181‚Äë1, the practical limits on the quantitative measurement of release rates by this method are from 1,8 micrograms per square centimetre per day to 500 micrograms per square centimetre per day. The quantitative measurement of release rates below this range will require an additional concentration step described in the text or the use of an analytical method with a lower limit of quantitation for PTPB in artificial seawater.

Previous Editions

Can’t find what you are looking for?

Please contact us at: