ISO 25498:2025
ISO 25498:2025 Microbeam analysis — Analytical electron microscopy — Selected area electron diffraction analysis using a transmission electron microscope
CDN $337.00
This publication was last reviewed and confirmed in 2025.
Microbeam analysis — Analytical electron microscopy — Selected area electron diffraction analysis using a transmission electron microscope
Description
This document specifies the method for selected area electron diffraction (SAED) analysis using a transmission electron microscope (TEM) to analyse thin crystalline specimens. This document applies to test areas of micrometres and sub-micrometres in size. The minimum diameter of the selected area in a specimen which can be analysed by this method is restricted by the spherical aberration coefficient of the objective lens of the microscope and approaches hundreds of nanometres for a modern TEM.
When the size of an analysed specimen area is smaller than the spherical aberration coefficient restriction, this document can also be used for the analysis procedure. However, because of the effect of spherical aberration and deviation of the specimen height position, some of the diffraction information in the pattern can be generated from outside of the area defined by the selected area aperture. In such cases, the use of microdiffraction (nano-beam diffraction) or convergent beam diffraction, where available, can be preferred.
This document is applicable to the acquisition of SAED patterns from crystalline specimens, indexing the patterns and calibration of the camera constant.
Edition
3
Published Date
2026-06-18
Status
PUBLISHED
Pages
42
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
This document specifies the method for selected area electron diffraction (SAED) analysis using a transmission electron microscope (TEM) to analyse thin crystalline specimens. This document applies to test areas of micrometres and sub-micrometres in size. The minimum diameter of the selected area in a specimen which can be analysed by this method is restricted by the spherical aberration coefficient of the objective lens of the microscope and approaches hundreds of nanometres for a modern TEM.
When the size of an analysed specimen area is smaller than the spherical aberration coefficient restriction, this document can also be used for the analysis procedure. However, because of the effect of spherical aberration and deviation of the specimen height position, some of the diffraction information in the pattern can be generated from outside of the area defined by the selected area aperture. In such cases, the use of microdiffraction (nano-beam diffraction) or convergent beam diffraction, where available, can be preferred.
This document is applicable to the acquisition of SAED patterns from crystalline specimens, indexing the patterns and calibration of the camera constant.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 20537:2025 Footwear – Identification of defects during visual inspection – Vocabulary
CDN $295.00 Add to cart -

ISO 8927:1991 Earth-moving machinery – Machine availability – Vocabulary
CDN $251.00 Add to cart -

ISO 2574:1994 Aircraft – Electrical cables – Identification marking
CDN $124.00 Add to cart -

ISO 80004:2011 Nanotechnologies – Vocabulary – Part 7: Diagnostics and therapeutics for healthcare
CDN $124.00 Add to cart