Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

TEMA 2026 Edition – Online Subscription Only

$

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 15SIH, 2nd Edition: Installation and Handling of Spoolable Reinforced Plastic Line Pipe

$

158

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 754, 4th Edition: Process Safety Performance Indicators for the Refining and Petrochemical Industries

$

393

BUY NOW

Placeholder headline

This is just a placeholder headline

ASME B31.1-2020: Power Piping

$

668

BUY NOW

Placeholder headline

This is just a placeholder headline

ASME B31.1-2022: Power Piping

$

668

BUY NOW

ISO 23971:2025

ISO 23971:2025 Surface chemical analysis — X-ray fluorescence analysis of particulate matter filters

CDN $296.00

This publication was last reviewed and confirmed in 2025.

Surface chemical analysis — X-ray fluorescence analysis of particulate matter filters

Description

This document gives guidance on sample preparation, and on qualitative and quantitative determination of elements in particulate matter collected on filtering membranes (PM filter) by energy dispersive X-ray Fluorescence (EDXRF) in different geometrical configurations. This document does not apply to PM filter sampling. This document only applies to the analysis of X-ray emission from filters that are probed using an X-ray beam as the exciting source. X-ray emissions generated by electron microscope are excluded[1].

This document is applicable under a range of contexts including, but not limited to, those highlighted in the introduction. The described method is generally applicable for the determination of elements with atomic number higher than 11 (Na) and having a deposited mass on the filter greater than 10 ng. The elements that can be identified and the detection limits depend on the specific instrumental configuration employed.

Various types of filtering membranes (filter) materials can be used, such as glass fibre, quartz fibre, cellulose, nylon, polycarbonate (PC) and polytetrafluoroethylene (PTFE). The entire filter, or portions of various sizes thereof, can be submitted for analysis.

NOTE            Reference free analysis, based on fundamental parameters is excluded, as the nature of the PM filter samples means that the parameters are not sufficiently well defined.

Edition

1

Published Date

2026-06-18

Status

PUBLISHED

Pages

27

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document gives guidance on sample preparation, and on qualitative and quantitative determination of elements in particulate matter collected on filtering membranes (PM filter) by energy dispersive X-ray Fluorescence (EDXRF) in different geometrical configurations. This document does not apply to PM filter sampling. This document only applies to the analysis of X-ray emission from filters that are probed using an X-ray beam as the exciting source. X-ray emissions generated by electron microscope are excluded[1].

This document is applicable under a range of contexts including, but not limited to, those highlighted in the introduction. The described method is generally applicable for the determination of elements with atomic number higher than 11 (Na) and having a deposited mass on the filter greater than 10 ng. The elements that can be identified and the detection limits depend on the specific instrumental configuration employed.

Various types of filtering membranes (filter) materials can be used, such as glass fibre, quartz fibre, cellulose, nylon, polycarbonate (PC) and polytetrafluoroethylene (PTFE). The entire filter, or portions of various sizes thereof, can be submitted for analysis.

NOTE            Reference free analysis, based on fundamental parameters is excluded, as the nature of the PM filter samples means that the parameters are not sufficiently well defined.

Previous Editions

Can’t find what you are looking for?

Please contact us at: