ISO 6877:2025 Dentistry — Endodontic obturating materials
CDN $251.00
This publication was last reviewed and confirmed in 2025.
Dentistry — Endodontic obturating materials
Description
This document specifies the requirements for the dimensions of various endodontic obturating materials and the radiopacity for polymeric points, polymeric-coated thermoplastic obturating carriers, non-point-shaped thermoplastic obturating material, or combinations of the above used for obturation of a root canal system. It also specifies numerical and colour-coding systems for designating the sizes of preformed endodontic obturating points, a method for determining the melt mass-flow rate for injection material, and the requirements for marking, labelling, packaging and the instructions for use.
Dental endodontic obturating points are marketed as sterilized or non-sterilized. Sterility is not included in this document. Any claim that the product is sterile is the manufacturer’s responsibility (see Table 3). This document does not apply to instruments or apparatus used with obturating materials that become plastic with heat or materials supporting a coronal restoration.
Clause 7
08D0C9EA79F9BACE118C8200AA004BA90B02000000080000000E000000530065006300740069006F006E005F007300650063005F0037000000
specifies marking, labelling and packaging, including the instructions for use. This document does not specify requirements or test methods for sterility. Reference to applicable national regulations, internationally accepted pharmacopoeia and standards for validating sterilization processes can apply.
Edition
4
Published Date
2026-06-19
Status
PUBLISHED
Pages
19
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
This document specifies the requirements for the dimensions of various endodontic obturating materials and the radiopacity for polymeric points, polymeric-coated thermoplastic obturating carriers, non-point-shaped thermoplastic obturating material, or combinations of the above used for obturation of a root canal system. It also specifies numerical and colour-coding systems for designating the sizes of preformed endodontic obturating points, a method for determining the melt mass-flow rate for injection material, and the requirements for marking, labelling, packaging and the instructions for use.
Dental endodontic obturating points are marketed as sterilized or non-sterilized. Sterility is not included in this document. Any claim that the product is sterile is the manufacturer's responsibility (see Table 3). This document does not apply to instruments or apparatus used with obturating materials that become plastic with heat or materials supporting a coronal restoration.
Clause 7 08D0C9EA79F9BACE118C8200AA004BA90B02000000080000000E000000530065006300740069006F006E005F007300650063005F0037000000 specifies marking, labelling and packaging, including the instructions for use. This document does not specify requirements or test methods for sterility. Reference to applicable national regulations, internationally accepted pharmacopoeia and standards for validating sterilization processes can apply.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 17988:2020 Dentistry – Corrosion test methods for dental amalgam
CDN $295.00 Add to cart -

ISO 3990:2023 Dentistry – Evaluation of antibacterial activity of dental restorative materials, luting materials, fissure sealants and orthodontic bonding or luting materials
CDN $251.00 Add to cart -

ISO 14356:2024 Dentistry – Duplicating material
CDN $295.00 Add to cart -

ISO 14569:2001 Dental materials – Guidance on testing of wear – Part 2: Wear by two- and/or three body contact
CDN $295.00 Add to cart