Search
×
FR

Placeholder headline

This is just a placeholder headline

TEMA 11th Edition – Book of Standards (Not for Resale)

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO 22040-3:2025 Life cycle management of concrete structures — Part 3: Execution stage

$

125

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO 2382-19:1989 Information processing systems — Vocabulary — Part 19: Analog computing

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO 6490-1:1985 Animal feeding stuffs — Determination of calcium content — Part 1: Titrimetric method

$

82

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO 8536-6:2025 Infusion equipment for medical use — Part 6: Freeze drying closures for infusion bottles

$

186

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO 21702:2019 Measurement of antiviral activity on plastics and other non-porous surfaces

$

289

BUY NOW

ISO 13196:2026

ISO 13196:2026 Soil quality — Screening soils for selected elements by energy-dispersive X-ray fluorescence spectrometry using a handheld or portable instrument

CDN $251.00

This publication was last reviewed and confirmed in 2026.

Soil quality — Screening soils for selected elements by energy-dispersive X-ray fluorescence spectrometry using a handheld or portable instrument

SKU: c6320863a36a Category:

Description

This document specifies the procedure for screening soils for selected elements using handheld or portable equipment for energy dispersive X-ray fluorescence spectrometry (ED-XRF). It covers the application of this screening method to obtain qualitative or semi-quantitative data to assist decisions on a sampling strategy for detailed assessment of soil quality employing laboratory analytical chemical methods.

NOTE 1        Screening methods generally provide qualitative or semi-quantitative concentration values that are indicative of concentration values, although occasionally they can give quantitative results under specific or limited conditions.

NOTE 2        The greater the effort applied to the pretreatment of soil samples, the better the analytical results that can be expected (see e.g. Reference [19]).

This document does not explicitly specify elements for which it is applicable, since the applicability depends on the performance of the apparatus and the objective of the screening. The elements which can be determined are limited by the performance of the instrument used, the concentrations of particular elements present in the soil, and the requirements of the investigation in terms of the minimum concentrations of concern (e.g. guideline value).

NOTE 3        The XRF measurements of As, Cd, Co, Cr, Cu, Hg, Mo, Ni, Pb, Sb, Sn, V and Zn were validated as described in Annex A.

NOTE 4        Annex B provides examples of when screening with a handheld ED-XRF spectrometer and a portable ED-XRF spectrometer can be useful.

This document does not provide guidance on how to use the equipment to provide quantitative data for use in detailed site assessments. This document does not cover how the results of multiple determinations are synthesized to address the objectives of an ED-XRF determination.

Edition

2

Published Date

2026-06-19

Status

PUBLISHED

Pages

22

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies the procedure for screening soils for selected elements using handheld or portable equipment for energy dispersive X-ray fluorescence spectrometry (ED-XRF). It covers the application of this screening method to obtain qualitative or semi-quantitative data to assist decisions on a sampling strategy for detailed assessment of soil quality employing laboratory analytical chemical methods.

NOTE 1        Screening methods generally provide qualitative or semi-quantitative concentration values that are indicative of concentration values, although occasionally they can give quantitative results under specific or limited conditions.

NOTE 2        The greater the effort applied to the pretreatment of soil samples, the better the analytical results that can be expected (see e.g. Reference [19]).

This document does not explicitly specify elements for which it is applicable, since the applicability depends on the performance of the apparatus and the objective of the screening. The elements which can be determined are limited by the performance of the instrument used, the concentrations of particular elements present in the soil, and the requirements of the investigation in terms of the minimum concentrations of concern (e.g. guideline value).

NOTE 3        The XRF measurements of As, Cd, Co, Cr, Cu, Hg, Mo, Ni, Pb, Sb, Sn, V and Zn were validated as described in Annex A.

NOTE 4        Annex B provides examples of when screening with a handheld ED-XRF spectrometer and a portable ED-XRF spectrometer can be useful.

This document does not provide guidance on how to use the equipment to provide quantitative data for use in detailed site assessments. This document does not cover how the results of multiple determinations are synthesized to address the objectives of an ED-XRF determination.

Previous Editions

Can’t find what you are looking for?

Please contact us at: