Search
×
FR

Placeholder headline

This is just a placeholder headline

ISO 22040-3:2025 Life cycle management of concrete structures — Part 3: Execution stage

$

125

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO 2382-19:1989 Information processing systems — Vocabulary — Part 19: Analog computing

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO 6490-1:1985 Animal feeding stuffs — Determination of calcium content — Part 1: Titrimetric method

$

82

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO 8536-6:2025 Infusion equipment for medical use — Part 6: Freeze drying closures for infusion bottles

$

186

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO 21702:2019 Measurement of antiviral activity on plastics and other non-porous surfaces

$

289

BUY NOW

ISO 32543-3:2026

ISO 32543-3:2026 Non-destructive testing — Characteristics of focal spots in industrial X-ray systems — Part 3: Measurement of the effective focal spot size of mini and micro focus X-ray tubes

CDN $186.00

This publication was last reviewed and confirmed in 2026.

Non-destructive testing — Characteristics of focal spots in industrial X-ray systems — Part 3: Measurement of the effective focal spot size of mini and micro focus X-ray tubes

Description

This document specifies a method for the measurement of focal spot sizes within the range of 5 µm to 300 µm of X-ray systems up to and including 225 kV tube voltage. This determination is based on the evaluation of an image with a dedicated focal spot that has been radiographically recorded using an edge and evaluated with a digital method.

The imaging quality and the resolution of X-ray images depend highly on the characteristics of the effective focal spot, in particular its size and the two-dimensional intensity distribution as seen from the detector plane.

For the characterization of commercial X-ray tube types (i.e. for advertising or trade), the nominal values of Annex A are preferred.

NOTE            The same procedure can be used at higher kilovoltages by agreement but the accuracy of the measurement can be poorer.

Edition

1

Published Date

2026-06-19

Status

PUBLISHED

Pages

14

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies a method for the measurement of focal spot sizes within the range of 5 µm to 300 µm of X-ray systems up to and including 225 kV tube voltage. This determination is based on the evaluation of an image with a dedicated focal spot that has been radiographically recorded using an edge and evaluated with a digital method.

The imaging quality and the resolution of X-ray images depend highly on the characteristics of the effective focal spot, in particular its size and the two-dimensional intensity distribution as seen from the detector plane.

For the characterization of commercial X-ray tube types (i.e. for advertising or trade), the nominal values of Annex A are preferred.

NOTE            The same procedure can be used at higher kilovoltages by agreement but the accuracy of the measurement can be poorer.