ISO 22040-3:2025 Life cycle management of concrete structures — Part 3: Execution stage

$

125

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO 2382-19:1989 Information processing systems — Vocabulary — Part 19: Analog computing

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO 6490-1:1985 Animal feeding stuffs — Determination of calcium content — Part 1: Titrimetric method

$

82

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO 8536-6:2025 Infusion equipment for medical use — Part 6: Freeze drying closures for infusion bottles

$

186

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO 21702:2019 Measurement of antiviral activity on plastics and other non-porous surfaces

$

289

BUY NOW

ISO 9846:2025

ISO 9846:2025 Solar energy — Calibration of a pyranometer using a pyrheliometer

CDN $337.00

This publication was last reviewed and confirmed in 2025.

Solar energy — Calibration of a pyranometer using a pyrheliometer

Description

This document specifies calibration methods for a pyranometer using a pyrheliometer as a reference instrument. Three methods are specified in this document.

a)       Alternating sun and shade method. This method uses a shading disc to alternately shade and unshade a pyranometer to compare with the tracking pyrheliometer. The test pyranometer can be horizontal, on a fixed tilt or tracking alongside the pyrheliometer.

b)       Continuous sun and shade method. In this method, a shaded calibrated reference pyranometer is used in addition to the reference pyrheliometer. The test pyranometer can be horizontal, on a fixed tilt or tracking alongside the reference pyrheliometer, but the reference pyranometer must be mounted in the same plane as the test pyranometer (most often on the horizontal).

c)        Collimation tube method. In this method, the test pyranometer is mounted on a solar tracker and is equipped with a collimation tube designed to allow the test pyranometer to have the same geometric view as the reference pyrheliometer for a direct comparison of the two instruments.

The methods in this document are applicable for calibration of all pyranometers provided that a proper uncertainty evaluation is performed. Unlike spectrally flat pyranometers, non-spectrally flat pyranometers have a sensitivity that strongly depends on the solar spectrum. Therefore, the calibration result can be valid under a more limited range of conditions.

The result of a calibration is the instrument sensitivity accompanied by an uncertainty. This document includes suggestions for uncertainty evaluation.

Edition

2

Published Date

2026-06-19

Status

PUBLISHED

Pages

44

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies calibration methods for a pyranometer using a pyrheliometer as a reference instrument. Three methods are specified in this document.

a)       Alternating sun and shade method. This method uses a shading disc to alternately shade and unshade a pyranometer to compare with the tracking pyrheliometer. The test pyranometer can be horizontal, on a fixed tilt or tracking alongside the pyrheliometer.

b)       Continuous sun and shade method. In this method, a shaded calibrated reference pyranometer is used in addition to the reference pyrheliometer. The test pyranometer can be horizontal, on a fixed tilt or tracking alongside the reference pyrheliometer, but the reference pyranometer must be mounted in the same plane as the test pyranometer (most often on the horizontal).

c)        Collimation tube method. In this method, the test pyranometer is mounted on a solar tracker and is equipped with a collimation tube designed to allow the test pyranometer to have the same geometric view as the reference pyrheliometer for a direct comparison of the two instruments.

The methods in this document are applicable for calibration of all pyranometers provided that a proper uncertainty evaluation is performed. Unlike spectrally flat pyranometers, non-spectrally flat pyranometers have a sensitivity that strongly depends on the solar spectrum. Therefore, the calibration result can be valid under a more limited range of conditions.

The result of a calibration is the instrument sensitivity accompanied by an uncertainty. This document includes suggestions for uncertainty evaluation.