ISO 24427:2025
ISO 24427:2025 Radiological protection — Medical proton accelerators — Requirements and recommendations for shielding design and evaluation
CDN $337.00
This publication was last reviewed and confirmed in 2025.
Radiological protection — Medical proton accelerators — Requirements and recommendations for shielding design and evaluation
Description
This document is applicable to the radiation shielding design and evaluation work for medical proton accelerators of proton energies ranging from 70 MeV to 250 MeV, with subsystems such as beam transport system and nozzle components.
The radiation protection recommendations given in this document cover the aspects relating to regulations, shielding design goals and other design criteria, role of the manufacturers, of the radiation protection officer or qualified expert, the medical physicist, the licensee and interactions between them, sources and radiations around a proton accelerator, shielding for accelerators and its subsystems (including shielding materials and transmission values, calculations for various room configurations, duct impact on radiation protection) and the radiological measurements.
FLASH proton therapy is not covered by this document.
NOTE 1 Annex A provides a list of the most used Monte-Carlo codes for shielding calculation.
NOTE 2 Annex B provides the analytical methods and the corresponding necessary data for shielding calculation.
NOTE 3 Annex C provides a set of examples on shielding calculation of barriers, maze and skyshine problems.
NOTE 4 Annex D provides radiation shielding consideration on special topics.
Edition
1
Published Date
2026-06-19
Status
PUBLISHED
Pages
49
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
This document is applicable to the radiation shielding design and evaluation work for medical proton accelerators of proton energies ranging from 70 MeV to 250 MeV, with subsystems such as beam transport system and nozzle components.
The radiation protection recommendations given in this document cover the aspects relating to regulations, shielding design goals and other design criteria, role of the manufacturers, of the radiation protection officer or qualified expert, the medical physicist, the licensee and interactions between them, sources and radiations around a proton accelerator, shielding for accelerators and its subsystems (including shielding materials and transmission values, calculations for various room configurations, duct impact on radiation protection) and the radiological measurements.
FLASH proton therapy is not covered by this document.
NOTE 1 Annex A provides a list of the most used Monte-Carlo codes for shielding calculation.
NOTE 2 Annex B provides the analytical methods and the corresponding necessary data for shielding calculation.
NOTE 3 Annex C provides a set of examples on shielding calculation of barriers, maze and skyshine problems.
NOTE 4 Annex D provides radiation shielding consideration on special topics.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 9687:2015 Dentistry – Graphical symbols for dental equipment
CDN $295.00 Add to cart -

ISO 17117:2022 Health informatics – Terminological resources – Part 2: Implementation Capability (TIC)
CDN $124.00 Add to cart -

ISO 21531:2009 Dentistry – Graphical symbols for dental instruments
CDN $186.00 Add to cart -

ISO 17097:2024 3-D human body scan data – Methods for the processing of human body scan data
CDN $186.00 Add to cart