CSA Z5359:16 (R2025)
CSA Z5359:16 (R2025) – Anaesthetic and respiratory equipment — Low-pressure hose assemblies for use with medical gases, medical vacuum, medical support gases, and anaesthetic gas scavenging systems (Adopted ISO 5359:2014, fourth edition, 2014-10-01, with Canadian deviations)
CDN $199.00
Anaesthetic and respiratory equipment — Low-pressure hose assemblies for use with medical gases, medical vacuum, medical support gases, and anaesthetic gas scavenging systems (Adopted ISO 5359:2014, fourth edition, 2014-10-01, with Canadian deviations)
Description
CSA Preface This is the third edition of CAN/CSA-Z5359, A naesthetic and respiratory equipment — Low-pressure hose assemblies for use with medical gases, medical vacuum, medical support gases, and anaesthetic gas scavenging systems, which is an adoption, with Canadian deviations, of ISO (International Organization for Standardization) Standard 5359 (fourth edition, 2014-10-01) titled Anaesthetic and respiratory equipment — Low-pressure hose assemblies for use with medical gases. It supersedes the previous edition, published in 2010 as CAN/CSA-Z5359, Low-pressure hose assemblies for use with medical gases (adopted ISO 5359:2008). In this third edition, the title has been modified to reflect the application of the Standard in Canada. In Canada, low-pressure hose assemblies are classified by Health Canada as Class II Medical Devices. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This International Standard specifies requirements for low-pressure hose assemblies intended for use with the following medical gases: — oxygen — nitrous oxide — medical air — helium — carbon dioxide — xenon — specified mixtures of the gases listed above — oxygen-enriched air — air for driving surgical tools — nitrogen for driving surgical tools and for use with vacuum. 1.2 *It applies to hose assemblies operating at pressures up to 1 400 kPa and for vacuum systems at pressures not greater than 60 kPa absolute. 1.3 This International Standard does not specify the dimensions and allocation of the gas-specific inlet and outlet connectors for the hose assemblies. NOTE 1 Specifications for the dimensions and allocation of diameter index safety system (DISS) connectors are specified in CGA V-5 [28]. NOTE 2 Specifications for the dimensions and allocation of sleeve indexed system (SIS) connectors are specified in AS 2896 [23]. NOTE 3 Dimensions and allocation of non-interchangeable screw-threaded (NIST) connectors are specified in ISO 18082 [11]. NOTE 4 Terminal units designed for quick connectors are specified in ISO 9170-1. 1.4 This International Standard does not specify requirements for coaxial hoses used for the supply and removal of air for driving surgical tools. 1.5 This International Standard does not specify the intended uses of hose assemblies. NOTE Environmental aspects are dealt with in Annex B.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
48
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
CSA Preface This is the third edition of CAN/CSA-Z5359, A naesthetic and respiratory equipment — Low-pressure hose assemblies for use with medical gases, medical vacuum, medical support gases, and anaesthetic gas scavenging systems, which is an adoption, with Canadian deviations, of ISO (International Organization for Standardization) Standard 5359 (fourth edition, 2014-10-01) titled Anaesthetic and respiratory equipment — Low-pressure hose assemblies for use with medical gases. It supersedes the previous edition, published in 2010 as CAN/CSA-Z5359, Low-pressure hose assemblies for use with medical gases (adopted ISO 5359:2008). In this third edition, the title has been modified to reflect the application of the Standard in Canada. In Canada, low-pressure hose assemblies are classified by Health Canada as Class II Medical Devices. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This International Standard specifies requirements for low-pressure hose assemblies intended for use with the following medical gases: — oxygen — nitrous oxide — medical air — helium — carbon dioxide — xenon — specified mixtures of the gases listed above — oxygen-enriched air — air for driving surgical tools — nitrogen for driving surgical tools and for use with vacuum. 1.2 *It applies to hose assemblies operating at pressures up to 1 400 kPa and for vacuum systems at pressures not greater than 60 kPa absolute. 1.3 This International Standard does not specify the dimensions and allocation of the gas-specific inlet and outlet connectors for the hose assemblies. NOTE 1 Specifications for the dimensions and allocation of diameter index safety system (DISS) connectors are specified in CGA V-5 [28]. NOTE 2 Specifications for the dimensions and allocation of sleeve indexed system (SIS) connectors are specified in AS 2896 [23]. NOTE 3 Dimensions and allocation of non-interchangeable screw-threaded (NIST) connectors are specified in ISO 18082 [11]. NOTE 4 Terminal units designed for quick connectors are specified in ISO 9170-1. 1.4 This International Standard does not specify requirements for coaxial hoses used for the supply and removal of air for driving surgical tools. 1.5 This International Standard does not specify the intended uses of hose assemblies. NOTE Environmental aspects are dealt with in Annex B.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CAN/CSA-Z900.2.5:22 – Lymphohematopoietic cells for transplantation
CDN $181.00 Add to cart -

CSA Z9170-1:19 (R2024) – Terminal units for medical gas pipeline systems – Part 1: Terminal units for use with compressed medical gases, vacuum, and anaesthetic gas scavenging systems (Adopted ISO 9170-1:2017, third edition, 2017-07, with Canadian deviations)
CDN $166.00 Add to cart -

CAN/CSA-Z900.2.1-17 (R2022) – Tissues for assisted reproduction
CDN $265.00 Add to cart -

CAN/CSA-Z900.2.2:22 – Tissues for transplantation
CDN $150.00 Add to cart