CSA Z316.8:18 (R2023)
CSA Z316.8:18 (R2023) – Requirements for the design, development, and validation of laboratory-developed tests used for the screening, diagnosis, and management of clinical conditions
CDN $118.00
Requirements for the design, development, and validation of laboratory-developed tests used for the screening, diagnosis, and management of clinical conditions
Description
Preface This is the first edition of CSA Z316.8, Requirements for the design, development, and validation of laboratory-developed tests used for the screening, diagnosis, and management of clinical conditions. CSA Group gratefully acknowledges that the development of this Standard was made possible, in part, by the financial and in-kind support from the Canadian Agency for Drugs and Technologies in Health (CADTH), the Canadian Society for Medical Laboratory Science (CSMLS), Alere ULC, Siemens, and Roche. This Standard was prepared by the Subcommittee on Lab-Developed Tests, under the jurisdiction of the Technical Committee on Medical Laboratory Quality Systems and the Strategic Steering Committee on Health Care Technology, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 General This Standard specifies the minimum requirements and best practices for the development, validation, and use of laboratory-developed tests in clinical and research laboratories for the screening, diagnosis, and management of clinical conditions. It does not provide specific details on how to achieve these requirements since they are provided in many other sources which are considered current best practice. References to these resources will be provided in this Standard. Note: See also Annex A for recommended resources. 1.2 Inclusions The Standard is intended to be used by organizations and individuals that are developing LDTs for the purpose of providing results that can be used in the screening, diagnosis, or management of clinical conditions. 1.3 Exclusions This Standard does not apply to the following: a) tests developed in-house but distributed outside of the laboratory; Note: Tests distributed outside of the laboratory fall outside the definition of “laboratory-developed test”. These are considered to be commercially distributed IVDDs and are regulated by Health Canada under the Medical Devices Regulations. b) LDTs that are developed by a laboratory or manufacturer solely for RUO or IUO (i.e., where there is no reporting of patient results); and c) accredited, non-clinical laboratories which have their own standard for development, validation, and use of LDTs. The Standard does not apply to laboratory-developed tests that are developed by a laboratory for RUO/ IUO until such time that the test becomes applied to clinical testing and has undergone suitable validation according to the requirements in this Standard. Notes: 1) The RUO/IUO labeling is meant to serve as a warning to prevent such products from being used in clinical diagnosis or patient management. However, clinical laboratories can validate tests using RUO reagents or components through their own procedures as described in this Standard, and subsequently offer it for clinical diagnostic use as a laboratory-developed test once validated. 2) Refer also to the Distribution of In Vitro Diagnostic Products Labeled for Research Use Only or Investigational Use Only. Guidance for Industry and Food and Drug Administration Staff document issued on November 25, 2013, U.S. Department of Health and Human Services, Food and Drug Administration, Center for Devices and Radiological Health, Office of In Vitro Diagnostic Device Evaluation and Safety. 1.4 Terminology In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
33
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Preface This is the first edition of CSA Z316.8, Requirements for the design, development, and validation of laboratory-developed tests used for the screening, diagnosis, and management of clinical conditions. CSA Group gratefully acknowledges that the development of this Standard was made possible, in part, by the financial and in-kind support from the Canadian Agency for Drugs and Technologies in Health (CADTH), the Canadian Society for Medical Laboratory Science (CSMLS), Alere ULC, Siemens, and Roche. This Standard was prepared by the Subcommittee on Lab-Developed Tests, under the jurisdiction of the Technical Committee on Medical Laboratory Quality Systems and the Strategic Steering Committee on Health Care Technology, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 General This Standard specifies the minimum requirements and best practices for the development, validation, and use of laboratory-developed tests in clinical and research laboratories for the screening, diagnosis, and management of clinical conditions. It does not provide specific details on how to achieve these requirements since they are provided in many other sources which are considered current best practice. References to these resources will be provided in this Standard. Note: See also Annex A for recommended resources. 1.2 Inclusions The Standard is intended to be used by organizations and individuals that are developing LDTs for the purpose of providing results that can be used in the screening, diagnosis, or management of clinical conditions. 1.3 Exclusions This Standard does not apply to the following: a) tests developed in-house but distributed outside of the laboratory; Note: Tests distributed outside of the laboratory fall outside the definition of "laboratory-developed test". These are considered to be commercially distributed IVDDs and are regulated by Health Canada under the Medical Devices Regulations. b) LDTs that are developed by a laboratory or manufacturer solely for RUO or IUO (i.e., where there is no reporting of patient results); and c) accredited, non-clinical laboratories which have their own standard for development, validation, and use of LDTs. The Standard does not apply to laboratory-developed tests that are developed by a laboratory for RUO/ IUO until such time that the test becomes applied to clinical testing and has undergone suitable validation according to the requirements in this Standard. Notes: 1) The RUO/IUO labeling is meant to serve as a warning to prevent such products from being used in clinical diagnosis or patient management. However, clinical laboratories can validate tests using RUO reagents or components through their own procedures as described in this Standard, and subsequently offer it for clinical diagnostic use as a laboratory-developed test once validated. 2) Refer also to the Distribution of In Vitro Diagnostic Products Labeled for Research Use Only or Investigational Use Only. Guidance for Industry and Food and Drug Administration Staff document issued on November 25, 2013, U.S. Department of Health and Human Services, Food and Drug Administration, Center for Devices and Radiological Health, Office of In Vitro Diagnostic Device Evaluation and Safety. 1.4 Terminology In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CAN/CSA-Z900.1:22 – Cells, tissues, and organs for transplantation: General requirements
CDN $265.00 Add to cart -

CSA Z9360-2:07 (R2022) – Anaesthetic and respiratory equipment – Heat and moisture exchangers (HMEs) for humidifying respired gases in humans – Part 2: HMEs for use with tracheostomized patients having minimum tidal volumes of 250 ml (Adopted ISO 9360-2:2001, first edition, 2001-04-15, with Canadian deviations)
CDN $115.00 Add to cart -

Z7000-18 (R2023) – General requirements for quality management and safety in perioperative settings
CDN $158.00 Add to cart -

CSA Z9170-1:19 (R2024) – Terminal units for medical gas pipeline systems – Part 1: Terminal units for use with compressed medical gases, vacuum, and anaesthetic gas scavenging systems (Adopted ISO 9170-1:2017, third edition, 2017-07, with Canadian deviations)
CDN $166.00 Add to cart